American journal of veterinary research · 1998
Effect of percutaneous endoscopic gastrostomy on gastric emptying in clinically normal cats.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Smith S A, Ludlow C L, Hoskinson J J, Butine M D, Goggin J M
Аннотация
OBJECTIVE: To assess the effect of percutaneous endoscopic gastrostomy (PEG) tube placement on gastric emptying in clinically normal cats.
ANIMALS: 8 healthy adult 3- to 5-year-old cats.
PROCEDURE: Cats were accommodated to the diet for 2 weeks prior to scintigraphy. Caloric needs were divided into 3 feedings/d. Food was withheld for 24 hours after tube placement, then was fed as a third of the caloric needs on day 1, two-thirds on day 2, and full caloric requirements thereafter. Gastric emptying was measured via nuclear scintigraphy. Labeled meals contained 111 MBq (3 mCi) of 99mTc-labeled disofenin. Sixty-second ventral scintigraphic images were acquired immediately, every 20 minutes for the first hour, then every 30 minutes for 4 hours after feeding. Each cat was evaluated 3 times prior to PEG tube placement. Cats were anesthetized, and 16-F mushroom-tipped Pezzar gastrostomy tubes were placed, using a video endoscope. Scintigraphy was repeated on days 1, 4, 7, 11, 14, and 21 after PEG tube placement.
RESULTS: Gastric emptying was faster with a PEG tube in place. Percentage of retained gastric activity was significantly lower after PEG for 150, 180, 210, and 240 minutes versus time before PEG tube placement.
CONCLUSION: Placement of a PEG tube does not delay gastric emptying in clinically normal cats.
CLINICAL RELEVANCE: Gastric retention of food, vomiting, and aspiration pneumonia after PEG tube placement may not be related to delayed gastric emptying.
ANIMALS: 8 healthy adult 3- to 5-year-old cats.
PROCEDURE: Cats were accommodated to the diet for 2 weeks prior to scintigraphy. Caloric needs were divided into 3 feedings/d. Food was withheld for 24 hours after tube placement, then was fed as a third of the caloric needs on day 1, two-thirds on day 2, and full caloric requirements thereafter. Gastric emptying was measured via nuclear scintigraphy. Labeled meals contained 111 MBq (3 mCi) of 99mTc-labeled disofenin. Sixty-second ventral scintigraphic images were acquired immediately, every 20 minutes for the first hour, then every 30 minutes for 4 hours after feeding. Each cat was evaluated 3 times prior to PEG tube placement. Cats were anesthetized, and 16-F mushroom-tipped Pezzar gastrostomy tubes were placed, using a video endoscope. Scintigraphy was repeated on days 1, 4, 7, 11, 14, and 21 after PEG tube placement.
RESULTS: Gastric emptying was faster with a PEG tube in place. Percentage of retained gastric activity was significantly lower after PEG for 150, 180, 210, and 240 minutes versus time before PEG tube placement.
CONCLUSION: Placement of a PEG tube does not delay gastric emptying in clinically normal cats.
CLINICAL RELEVANCE: Gastric retention of food, vomiting, and aspiration pneumonia after PEG tube placement may not be related to delayed gastric emptying.