Integrated hemodynamic sensing, electrical sensing, and ventricular pacing from a novel substernal lead: An acute human study.

Cai Cheng, Gu Kai, Gaskill Bob, Ding Xiangwei, Li Yanhui, Chen Minglong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Implantable cardioverter defibrillators rely primarily on electrical signals to guide therapy. Hemodynamic sensing may provide complementary information about the immediate physiological consequences of arrhythmias.

OBJECTIVE

In this study, we evaluated the acute feasibility and performance of a 3-dimensional substernal shock lead that integrates hemodynamic sensing, electrical sensing, and ventricular pacing.

METHODS

This prospective first-in-human feasibility study enrolled 5 patients undergoing cardiac surgery or epicardial ventricular tachycardia (VT) ablation. A substernal shock lead was temporarily placed through a percutaneous subxiphoid approach using a dedicated delivery system. Lead placement and removal, adverse events, synchronized sensor signals, surface electrocardiograms, substernal electrograms, and pacing thresholds were assessed.

RESULTS

Lead placement and removal were successful in all patients without device- or procedure-related acute adverse events. Interpretable hemodynamic signals were obtained in all 5 patients and showed stable beat-to-beat temporal correspondence with the electrocardiogram and distinct rhythm-associated patterns across sinus rhythm, atrial fibrillation, VT, and ventricular fibrillation. All 147 VT episodes had interpretable hemodynamic-index recordings. The hemodynamic index decreased abruptly during VT and recovered after arrhythmia termination. Corresponding changes in the hemodynamic index were observed during transitions among VT, ventricular fibrillation, and sinus rhythm. Ventricular capture was achieved in all 5 patients at 11-17 V (mean, 13.8 V) at 0.5 ms.

CONCLUSION

Acute placement of this multifunctional substernal lead was feasible and enabled integrated hemodynamic and electrical sensing with acute ventricular capture. These findings provide preliminary human support for further development of physiology-guided extravascular implantable cardioverter defibrillator systems; chronic performance and clinical validation of the hemodynamic sensing algorithm require further study.

Для цитирования: Cai Cheng, Gu Kai, Gaskill Bob, Ding Xiangwei, Li Yanhui, Chen Minglong. Integrated hemodynamic sensing, electrical sensing, and ventricular pacing from a novel substernal lead: An acute human study.. Heart rhythm. 2026. DOI: 10.1016/j.hrthm.2026.08.047.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.