DOI 10.1371/journal.pntd.0002078

Медицинская библиотека · PLoS neglected tropical diseases · 2013

Electrocardiographic abnormalities in Trypanosoma cruzi seropositive and seronegative former blood donors.

Ribeiro Antonio L, Sabino Ester C, Marcolino Milena S, Salemi Vera M C, Ianni Barbara M, Fernandes Fábio, Nastari Luciano, Antunes André, Menezes Márcia, Oliveira Cláudia Di Lorenzo, Sachdev Vandana, Carrick Danielle M, Busch Michael P, Murphy Eduard L, NHLBI Retrovirus Epidemiology Donor Study-II (REDS-II), International Component

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Blood donor screening leads to large numbers of new diagnoses of Trypanosoma cruzi infection, with most donors in the asymptomatic chronic indeterminate form. Information on electrocardiogram (ECG) findings in infected blood donors is lacking and may help in counseling and recognizing those with more severe disease.

OBJECTIVES

To assess the frequency of ECG abnormalities in T.cruzi seropositive relative to seronegative blood donors, and to recognize ECG abnormalities associated with left ventricular dysfunction.

METHODS

The study retrospectively enrolled 499 seropositive blood donors in São Paulo and Montes Claros, Brazil, and 483 seronegative control donors matched by site, gender, age, and year of blood donation. All subjects underwent a health clinical evaluation, ECG, and echocardiogram (Echo). ECG and Echo were reviewed blindly by centralized reading centers. Left ventricular (LV) dysfunction was defined as LV ejection fraction (EF)<0.50%.

RESULTS

Right bundle branch block and left anterior fascicular block, isolated or in association, were more frequently found in seropositive cases (p<0.0001). Both QRS and QTc duration were associated with LVEF values (correlation coefficients -0.159,p<0.0003, and -0.142,p = 0.002) and showed a moderate accuracy in the detection of reduced LVEF (area under the ROC curve: 0.778 and 0.790, both p<0.0001). Several ECG abnormalities were more commonly found in seropositive donors with depressed LVEF, including rhythm disorders (frequent supraventricular ectopic beats, atrial fibrillation or flutter and pacemaker), intraventricular blocks (right bundle branch block and left anterior fascicular block) and ischemic abnormalities (possible old myocardial infarction and major and minor ST abnormalities). ECG was sensitive (92%) for recognition of seropositive donors with depressed LVEF and had a high negative predictive value (99%) for ruling out LV dysfunction.

CONCLUSIONS

ECG abnormalities are more frequent in seropositive than in seronegative blood donors. Several ECG abnormalities may help the recognition of seropositive cases with reduced LVEF who warrant careful follow-up and treatment.

Для цитирования: Ribeiro Antonio L, Sabino Ester C, Marcolino Milena S, Salemi Vera M C, Ianni Barbara M, Fernandes Fábio, Nastari Luciano, Antunes André, Menezes Márcia, Oliveira Cláudia Di Lorenzo, Sachdev Vandana, Carrick Danielle M, Busch Michael P, Murphy Eduard L, NHLBI Retrovirus Epidemiology Donor Study-II (REDS-II), International Component. Electrocardiographic abnormalities in Trypanosoma cruzi seropositive and seronegative former blood donors.. PLoS neglected tropical diseases. 2013. DOI: 10.1371/journal.pntd.0002078.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.