DOI 10.1007/s11748-013-0216-6

Медицинская библиотека · General thoracic and cardiovascular surgery · 2013

Patient-prosthesis mismatch in patients with aortic valve replacement.

Kaminishi Yuichiro, Misawa Yoshio, Kobayashi Junjiro, Konishi Hiroaki, Miyata Hiroaki, Motomura Noboru, Takamoto Shin-ichi, Japan Cardiovascular Surgery Database Organization

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Patient-prosthesis mismatch (PPM) may affect clinical outcomes in patients with aortic valve replacement (AVR). We retrospectively examined the PPM in patients with isolated AVR in the Japan Adult Cardiovascular Surgery Database (JACVSD).

METHODS

We examined all patients with isolated AVR between January 1, 2008 and December 31, 2009. The JACVSD data collection form has a total of 255 variables. We defined PPM as an effective orifice area index of ≤ 0.85 m(2)/cm(2).

RESULTS

PPM was observed in 306 of 3,609 cases analyzed, PPM rate was 8.5 %. Body surface area was larger and body mass index was higher in the PPM group than the non-PPM group (P < 0.001). Patients with PPM were older (P = 0.001) and had a higher prevalence of diabetes (P = 0.004), dyslipidemia (P < 0.001), hypertension (P < 0.001), cerebrovascular disease (P = 0.031), old myocardial infarction (P = 0.006), previous percutaneous coronary artery intervention (P = 0.001), coronary artery disease (P = 0.018), and aortic valve stenosis (P < 0.001). Perioperative blood transfusion (P < 0.001) and dialysis (P = 0.005) were more frequent in the PPM group. Postoperative ventilation (P = 0.004) and intensive care unit stay (P = 0.004) were significantly longer in the PPM group.

CONCLUSIONS

Age, aortic valve stenosis, dyslipidemia, hypertension, old myocardial infarction, previous percutaneous coronary artery intervention, diabetes mellitus, cerebrovascular disease, and high body mass index were the risk factors for PPM. PPM was not an independent risk factor for short-term mortality.

Для цитирования: Kaminishi Yuichiro, Misawa Yoshio, Kobayashi Junjiro, Konishi Hiroaki, Miyata Hiroaki, Motomura Noboru, Takamoto Shin-ichi, Japan Cardiovascular Surgery Database Organization. Patient-prosthesis mismatch in patients with aortic valve replacement.. General thoracic and cardiovascular surgery. 2013. DOI: 10.1007/s11748-013-0216-6.