JACC. Case reports · 2026
Iatrogenic Complete Anterolateral Papillary Muscle Rupture Following Transcatheter Gelatin Sponge Embolization for Coronary Artery Perforation.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yokomori Hiroki, Niikura Hiroki, Yokouchi Yuki, Ide Shiho, Hashimoto Go, Iijima Raisuke, Takahashi Kei, Nakamura Masato, Hara Hidehiko
Аннотация
BACKGROUND: Iatrogenic papillary muscle rupture (iPMR) is a rare but fatal complication of catheter interventions. No previous report to our knowledge has described iPMR with pathologic findings following transcatheter embolization for guidewire perforation of coronary artery.
CASE SUMMARY: An 83-year-old man with unstable angina underwent a percutaneous coronary intervention. On the same night as the percutaneous coronary intervention, a guidewire perforation of the left circumflex artery side branch was identified, resulting in cardiac tamponade. Transcatheter embolization of the culprit vessel was performed using gelatin sponge particles. Severe acute mitral regurgitation with circulatory collapse developed 30 hours later secondary to anterolateral iPMR. Despite mechanical circulatory support, the patient died 2 days after mitral regurgitation onset.
DISCUSSION: Pathologic findings revealed embolic materials within the anterolateral papillary muscle, causing new papillary muscle necrosis and rupture.
TAKE-HOME MESSAGE: Gelatin sponge embolization may achieve hemostasis in coronary guidewire perforation but poses a significant risk of iPMR.
CASE SUMMARY: An 83-year-old man with unstable angina underwent a percutaneous coronary intervention. On the same night as the percutaneous coronary intervention, a guidewire perforation of the left circumflex artery side branch was identified, resulting in cardiac tamponade. Transcatheter embolization of the culprit vessel was performed using gelatin sponge particles. Severe acute mitral regurgitation with circulatory collapse developed 30 hours later secondary to anterolateral iPMR. Despite mechanical circulatory support, the patient died 2 days after mitral regurgitation onset.
DISCUSSION: Pathologic findings revealed embolic materials within the anterolateral papillary muscle, causing new papillary muscle necrosis and rupture.
TAKE-HOME MESSAGE: Gelatin sponge embolization may achieve hemostasis in coronary guidewire perforation but poses a significant risk of iPMR.