MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-023-01511-1

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023

Outcomes of cavotricuspid isthmus-dependent flutter ablation: randomized study comparing single vs. multiple catheter procedures-the SIMPLE study.

Penela Diego, Chauca Alfredo, Fernández-Armenta Juan, Pavón Ricardo, Benito Begoña, Acosta Juan, Lozano Jose Miguel, Falasconi Giulio, San Antonio Rodolfo, Soto-Iglesias David, Martí-Almor Julio, Ordoñez Augusto, Bellido Aldo, Carreño José Miguel, Matiello Maria, Cano Lucas, Pedrote Alonso, Viveros Daniel, Alderete Jose, Francia Pietro, Algarra-Cullell Maria, Silva Etelvino, Meca-Santamaria Julia, Franco Paula, Cappato Riccardo, Berruezo Antonio

Рандомизированное исследованиеМногоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation.

METHODS

In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms.

RESULTS

128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71).

CONCLUSIONS

The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.

Для цитирования: Penela Diego, Chauca Alfredo, Fernández-Armenta Juan, Pavón Ricardo, Benito Begoña, Acosta Juan, Lozano Jose Miguel, Falasconi Giulio, San Antonio Rodolfo, Soto-Iglesias David, Martí-Almor Julio, Ordoñez Augusto, Bellido Aldo, Carreño José Miguel, Matiello Maria, Cano Lucas, Pedrote Alonso, Viveros Daniel, Alderete Jose, Francia Pietro, Algarra-Cullell Maria, Silva Etelvino, Meca-Santamaria Julia, Franco Paula, Cappato Riccardo, Berruezo Antonio. Outcomes of cavotricuspid isthmus-dependent flutter ablation: randomized study comparing single vs. multiple catheter procedures-the SIMPLE study.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2023. DOI: 10.1007/s10840-023-01511-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление