MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1444-0938.2011.00649.x

Медицинская библиотека · Clinical & experimental optometry · 2011

Visual outcome of Soflens Daily Disposable and Soflens Daily Disposable for Astigmatism in subjects with low astigmatism.

Cho Pauline, Cheung Sin Wan, Charm Jessie

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare the visual outcome of Soflens Daily Disposables and Soflens Daily Disposable for Astigmatism (Bausch & Lomb, Rochester, NY, USA) when worn by subjects with low astigmatism.

METHODS

Forty-one subjects (aged 19 to 40 years) with myopia between 0.50 D to 6.00 D and astigmatism not more than -1.25 D in at least one eye were recruited and fitted with spherical and toric soft contact lenses in this double-masked, non-dispensing cross-over study. High and low contrast logMAR visual acuities were measured over the lenses. At the end of the study, each subject was asked to complete a questionnaire on vision, initial comfort and ease of handling of the two lens types.

RESULTS

Monocular and binocular high and low contrast logMAR visual acuities were significantly better with the toric lenses compared with the spherical lenses (p < 0.01). Results from the questionnaire showed a significantly higher grade for vision with the toric lenses than with the spherical lenses (p = 0.003) but no significant differences in initial comfort and ease of handling between spherical and toric lenses (p > 0.21).

CONCLUSIONS

The results of the present study show that both subjective and objective vision in myopic subjects with low astigmatism improves significantly when corrected with toric lenses compared with spherical lenses.

Для цитирования: Cho Pauline, Cheung Sin Wan, Charm Jessie. Visual outcome of Soflens Daily Disposable and Soflens Daily Disposable for Astigmatism in subjects with low astigmatism.. Clinical & experimental optometry. 2011. DOI: 10.1111/j.1444-0938.2011.00649.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.