Endoscopic salvage for afferent loop syndrome: the antegrade lumen-apposing metal stent technique.
Аннотация
BACKGROUND AND AIMS: Afferent loop syndrome (ALS) is a rare postgastrectomy condition with biliopancreatic limb obstruction. Revision surgery carries high morbidity in patients with hostile anatomy. We aimed to demonstrate the feasibility of a double-scope, antegrade EUS-guided lumen-apposing metal stent (LAMS) enteroenterostomy as an endoscopic alternative in the management of complex ALS.
METHODS
A patient with extensive prior gastric surgery presented with ALS. With a double-scope antegrade technique, a pediatric gastroscope (GIF-XP190 N; Olympus, Tokyo, Japan) was used to cannulate the afferent limb to place a guidewire, and a linear echoendoscope (GF-UCT180; Fujifilm, Tokyo, Japan) was advanced into the blind loop. The pediatric gastroscope was reintroduced into the efferent limb, which was water-distended to approximately 3 cm in diameter to achieve sonographic apposition. Under combined EUS and fluoroscopic guidance, a 15- × 15-mm electrocautery-enhanced LAMS (Boston Scientific, Marlborough, Mass, USA) was deployed to create an enteroenterostomy.
RESULTS
Postdeployment contrast confirmed optimal position and immediate patency without leak. Symptoms resolved rapidly; the patient resumed a diet within days and gained weight. Abdominal radiography showed progressive LAMS expansion without adverse events.
CONCLUSIONS
Double-scope antegrade EUS-guided LAMS placement safely decompressed the afferent limb in our patient, restoring enteral flow and avoiding high-morbidity reoperation. This technique merits consideration within multidisciplinary care and warrants larger comparative studies to define long-term outcomes.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.