DOI 10.4103/ijdvl.ijdvl_513_18
Adult-onset Still's disease presenting as blotchy and flagellate pigmentation.
Аннотация
PURPOSE: The objective of this study was to evaluate and compare the clinical performance of samfilcon A, a unique, polyvinylpyrrolidone (PVP)-containing, silicone hydrogel contact lens with that of the balafilcon A silicone hydrogel contact lens when worn on a 7-day extended wear basis.
SUBJECTS AND
METHODS
A total of 669 subjects completed this 12-month, controlled, parallel group, masked, randomized study; of these, 340 wore samfilcon A lenses and 329 balafilcon A lenses. Subjects wore their respective assigned lenses bilaterally on a 7-day extended wear basis. On the seventh night of each wearing week, lenses were removed, cleaned, and disinfected using Biotrue multi-purpose solution (MPS), then re-inserted the following morning. Lenses were replaced with new lenses monthly. At each follow-up visit, investigators completed a slit lamp evaluation, and subjects rated lenses based upon a predefined set of performance criteria.
RESULTS
The samfilcon A lens performed comparably to the balafilcon A lens in terms of most graded and ungraded slit lamp findings, differing significantly only for corneal staining Grade 2 or greater, which favored samfilcon A, and anterior segment abnormalities, which favored balafilcon A. Subjects rated both lenses highly when queried about various lens-wearing characteristics. When comparing the number of subjects with findings on either eye on at least one follow-up visit, the two lenses were comparable in many aspects but favored samfilcon A with respect to cleanliness upon removal, overall comfort, comfort at end of day, dryness, vision, vision in low light, vision at end of day, and overall impression (all p < 0.05).
CONCLUSION
While subjects rated both highly, samfilcon A lenses worn for 7-day extended wear and replaced on a monthly basis performed comparably to or better than balafilcon A lenses when worn for the same 7-day wear time and replacement cycle.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.