DOI 10.1016/j.hrthm.2026.08.001
Body mass index, acute atrial fibrillation termination, and long-term recurrence after catheter ablation for persistent atrial fibrillation: Insights from a large contemporary cohort.
Аннотация
BACKGROUND
Obesity is a modifiable risk factor for atrial fibrillation (AF), but its relationship with acute procedural response and long-term rhythm durability after ablation for persistent AF (PeAF) remains incompletely defined.
OBJECTIVE
To evaluate the association of body mass index (BMI) with acute AF termination and long-term atrial arrhythmia recurrence after first-time radiofrequency catheter ablation for PeAF.
METHODS
We analyzed prospective data from 7559 consecutive patients with clinically documented PeAF undergoing first-time radiofrequency catheter ablation between January 2018 and March 2025. Patients were classified according to World Health Organization BMI categories. The primary outcome was atrial arrhythmia recurrence after a 3-month blanking period.
RESULTS
During a median follow-up of 41 months, atrial arrhythmia recurrence occurred in 3494 patients (46.2%). In the fully adjusted model, higher BMI was associated with recurrence as a continuous variable (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.02-1.04). Compared with normal-weight patients, patients with overweight and obesity had higher recurrence risks (HR, 1.15; 95% CI, 1.06-1.24; and HR, 1.31; 95% CI, 1.18-1.45, respectively). Acute AF termination occurred in 832 patients (11.0%) and decreased with increasing BMI. Higher BMI was associated with lower odds of acute AF termination (odds ratio, 0.95; 95% CI, 0.93-0.97). Findings were consistent across sensitivity analyses.
CONCLUSION
In patients with PeAF undergoing first-time radiofrequency ablation, higher BMI was associated with lower acute AF termination and increased long-term recurrence. BMI may serve as a practical marker for preprocedural risk stratification.