MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2017.08.004

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2017

Evaluating tear clearance rate with optical coherence tomography.

Garaszczuk Izabela K, Mousavi Maryam, Cervino Exposito Alejandro, Bartuzel Maciej M, Montes-Micó Robert, Iskander D Robert

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality.

METHODS

TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining.

RESULTS

The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r2=0.319, p<0.001), blinking frequency (r2=0.138, p<0.01), tear film osmolarity (r2=0.133, p<0.01) and subject's age (r2=0.095, p<0.05).

CONCLUSIONS

Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit.

Для цитирования: Garaszczuk Izabela K, Mousavi Maryam, Cervino Exposito Alejandro, Bartuzel Maciej M, Montes-Micó Robert, Iskander D Robert. Evaluating tear clearance rate with optical coherence tomography.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2017. DOI: 10.1016/j.clae.2017.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.