DOI 10.2459/jcm.0000000000001886
Progressive reduction in complications of cryoballoon pulmonary vein isolation for atrial fibrillation.
Аннотация
AIMS: Cryoballoon pulmonary vein isolation (CB-PVI) has become an established treatment for atrial fibrillation and, recently, it has been proposed as first-line therapy for the treatment of paroxysmal atrial fibrillation. Nevertheless, some concerns remain regarding the safety of this thermal energy-based approach. This prospective analysis aimed to assess the procedural complication rate of CB-PVI in a large cohort of consecutive patients over a nearly 13-year period.
METHODS
Data from consecutive patients treated with CB-PVI for atrial fibrillation between April 2012 and November 2024 in 35 institutions were analyzed. All complications occurring from patient admission up to 3 months postprocedure were recorded.
RESULTS
Eight thousand five hundred and thirty-one patients were enrolled (27.2% women, mean age 60.8 ± 10.5 years, 75.7% with paroxysmal atrial fibrillation), and 211 of them (2.49%) experienced at least one procedural adverse event related to CB-PVI. Of note, one cardiac tamponade event led to a sudden cardiovascular death (0.01%). A statistically significant reduction in complication rates was observed amongst three cohorts of product usage: from 2012 to 2015 ( n = 1326 patients, 5.0%), from 2016 to 2019 ( n = 3487 patients, 2.5%), and from 2020 to 2024 ( n = 3718 patients, 1.6%; P < 0.001). Multivariate logistic regression analysis identified use of the Arctic Front Advance PRO balloon as a significant protective factor against complications [OR 0.26 (0.17-0.40), P < 0.001], whereas female sex emerged as the strongest predictor of adverse events [OR 1.54 (1.11-2.13), P < 0.01].
CONCLUSION
CB-PVI for atrial fibrillation ablation has proven to be a well tolerated procedure, with a steadily decreasing complication rate over time.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.