MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-024-11205-5

Медицинская библиотека · European radiology · 2024

Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis.

Li Meng, Zhang Hui, Liu Jia-Ni, Zhong Fei, Zheng Song-Yuan, Zhang Jing, Chen Shi-Xian, Lin Rui-Feng, Zhang Kang-Yu, Liu Xiao-Min, Xu Yi-Kai, Li Juan

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to compare the performance of different dual-energy computed tomography (DECT) technologies in detecting monosodium urate (MSU) crystals and evaluate the potential clinical value of novel second-generation dual-layer spectral detector CT (dlDECT) in gouty arthritis.

METHODS

Using data collected from a tertiary hospital, we examined the diagnostic accuracy of different DECT technologies for the diagnosis of MSU. We used two standards: (1) demonstration of MSU crystals in synovial fluid (gold) and (2) 2015 ACR/EULAR gout classification criteria (silver). Furthermore, six novel spectral parameters derived from dlDECT were quantitatively calculated and analyzed for MSU diagnostic efficiency.

RESULTS

Of the 243 patients with 387 joints, 68 (27.98%) had synovial fluid analysis. Compared with the gold standard, MSU diagnostic accuracy statistics for dlDECT, dual-source DECT (dsDECT) and rapid kilovolt peak switching DECT (rsDECT) were as follows: area under the curve (AUC): 0.85, 0.80 and 0.75, respectively. Findings were replicated compared with the silver standard. Multiparametric analysis in dlDECT demonstrated the highest MSU detection rate (92.86%), significantly higher than rsDECT (42.08%) and dsDECT (85.80%). Among novel parameters in dlDECT, Calcium-suppressed index 25 (CaSupp-I 25) exhibited the best performance in distinguishing materials (MSU, muscle, and bone), with an AUC of 0.992. The differentiation was also aided by histograms, scatter plots, and attenuation curves.

CONCLUSION

The novel dlDECT is likely not inferior to other DECT technologies in MSU detection, especially its spectral parameter CaSupp-I 25. Multiparameter analysis showed the potential value for detecting MSU crystals in gouty arthritis, providing valuable clinical insights for gout diagnosis.

KEY POINTS: Question The performance of different DECT technologies in detecting monosodium urate (MSU), and the value of dual-layer spectral detector CT (dlDECT) in gouty arthritis remains unclear. Findings The dlDECT was likely not inferior to other DECT technologies in MSU detection, and its multiparametric analysis provided valuable information for MSU diagnosis. Clinical relevance Novel dlDECT may improve the accurate detection of MSU crystals in gouty arthritis compared to other DECT technologies, providing valuable clinical insights and potentially improving patient outcomes for more precise gout diagnosis.

Для цитирования: Li Meng, Zhang Hui, Liu Jia-Ni, Zhong Fei, Zheng Song-Yuan, Zhang Jing, Chen Shi-Xian, Lin Rui-Feng, Zhang Kang-Yu, Liu Xiao-Min, Xu Yi-Kai, Li Juan. Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis.. European radiology. 2024. DOI: 10.1007/s00330-024-11205-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.