DOI 10.1111/ceo.14528

Медицинская библиотека · Clinical & experimental ophthalmology · 2025

High-Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance.

Sarossy Marc G, Rezk Sandy, Li Dongzhe, Hadoux Xavier, Jannaud Maxime, Coote Michael A, Ang Ghee Soon, van Wijngaarden Peter, Martin Keith R, Wu Zhichao

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

To compare the performance of high-resolution microperimetry testing against standard automated perimetry (SAP) for detecting glaucomatous damage seen on optical coherence tomography (OCT) scans.

METHODS

250 eyes from 200 individuals underwent high-resolution microperimetry testing of a hemifield using a stimulus pattern optimised to sample typical arcuate patterns of visual field loss in glaucoma. SAP was performed using a 24-2 stimulus pattern. The presence of glaucomatous damage in each hemifield was subsequently independently assessed by two graders based on a circumpapillary OCT circle scan, 6×6 mm optic disc-centred OCT volume scan, and 15×15 mm widefield OCT volume scan.

RESULTS

The hemifield-based mean total deviation (MTD) and pointwise sensitivity standard deviation (PSD) for high-resolution microperimetry and SAP were both independently associated with the presence of glaucomatous damage in multivariable logistic regression analyses (p ≤ 0.046). Prediction models developed using these two parameters showed significantly higher performance with high-resolution microperimetry compared to SAP (partial area under the receiver operating characteristic curve [pAUC] = 0.86 and 0.75 respectively; p = 0.007). The performance of microperimetry decreased with decreasing resolution when the MTD and PSD values were derived from every second, third, and sixth test locations (pAUC = 0.85 [p = 0.16], 0.85 [p = 0.044] and 0.84 [p < 0.001] respectively), but they were all significantly better than SAP (p ≤ 0.028 for all).

CONCLUSIONS

High-resolution microperimetry enabled improved performance for detecting glaucomatous damage compared to SAP, highlighting the potential value of fundus-tracking and higher-resolution sampling for the detection of glaucomatous visual field loss.

Для цитирования: Sarossy Marc G, Rezk Sandy, Li Dongzhe, Hadoux Xavier, Jannaud Maxime, Coote Michael A, Ang Ghee Soon, van Wijngaarden Peter, Martin Keith R, Wu Zhichao. High-Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance.. Clinical & experimental ophthalmology. 2025. DOI: 10.1111/ceo.14528.