MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2478/jccm-2020-0023

Медицинская библиотека · Journal of critical care medicine (Universitatea de Medicina si Farmacie din Targu-Mures) · 2020

Hypoxic Respiratory Failure Further Complicated During Airway Exchange Catheter Placement.

Ali Osman, Verceles Avelino C, Barrett Matthew L, Franklin Christopher M, Khan Imran, Naderi Negar, McCurdy Michael T

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

An airway exchange catheter is a hollow-lumen tube able to deliver oxygen and maintain access to a difficult endotracheal airway. This case report demonstrates an undocumented complication associated with an airway exchange catheter and jet ventilation, particularly in a patient with reduced airway diameter due to thick endotracheal secretions. Due to the frequent use of airway exchange catheters in the intensive care unit, this report highlights an adverse event of bilateral pneumothoraces that can be encountered by clinicians.

CASE PRESENTATION: This case report describes a 24-year-old female with severe adult respiratory distress syndrome and thick endotra-cheal secretions whose hospital course was complicated by bilateral pneumothoraces resulting from the use of an airway exchange catheter connected to jet ventilation. During the exchange, the catheter occluded the narrowed endotracheal tube to create a one-way valve that led to excessive lung inflation.

CONCLUSION

Airway exchange catheters used with jet ventilation in a patient with a narrowed endotracheal tube and reduced lung compliance have the potential risk of causing a pneumothorax. Clinicians should avoid temporary concomitant oxygenation via jet ventilation in patients with these findings and reserve the use of airway exchange catheters for difficult airways.

Для цитирования: Ali Osman, Verceles Avelino C, Barrett Matthew L, Franklin Christopher M, Khan Imran, Naderi Negar, McCurdy Michael T. Hypoxic Respiratory Failure Further Complicated During Airway Exchange Catheter Placement.. Journal of critical care medicine (Universitatea de Medicina si Farmacie din Targu-Mures). 2020. DOI: 10.2478/jccm-2020-0023.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.