Pediatrics · 2014
Extreme neonatal hyperbilirubinemia and a specific genotype: a population-based case-control study.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Petersen Jesper Padkær, Henriksen Tine Brink, Hollegaard Mads Vilhelm, Vandborg Pernille Kure, Hougaard David Michael, Thorlacius-Ussing Ole, Ebbesen Finn
Аннотация
OBJECTIVES: Extreme hyperbilirubinemia (plasma bilirubin ≥ 24.5 mg/dL) is an important risk factor for severe bilirubin encephalopathy. Several risk factors for hyperbilirubinemia are known, but in a large number of patients, a causal factor is never established. UGT1A1 is the rate-limiting enzyme in bilirubin's metabolism. The genotype of Gilbert syndrome, the UGT1A1*28 allele, causes markedly reduced activity of this enzyme, but its association with neonatal hyperbilirubinemia is uncertain and its relationship with extreme hyperbilirubinemia has not been studied. We examined whether the UGT1A1*28 allele is associated with extreme hyperbilirubinemia.
METHODS: The UGT1A1*28 allele was assessed in a case-control study of 231 white infants who had extreme hyperbilirubinemia in Denmark from 2000 to 2007 and 432 white controls. Cases were identified in the Danish Extreme Hyperbilirubinemia Database that covers the entire population. Genotypes were obtained through the Danish Neonatal Screening Biobank. Subgroup analysis was done for AB0 incompatible cases.
RESULTS: No association was found between the UGT1A1*28 allele and extreme hyperbilirubinemia. With the common genotype as reference, the odds ratio of extreme hyperbilirubinemia was 0.87 (range, 0.68-1.13) for UGT1A1*28 heterozygotes and 0.77 (range, 0.46-1.27) for homozygotes. Also, no association was found for AB0 incompatible cases.
CONCLUSIONS: The UGT1A1*28 allele was not associated with risk for extreme hyperbilirubinemia in this study.
METHODS: The UGT1A1*28 allele was assessed in a case-control study of 231 white infants who had extreme hyperbilirubinemia in Denmark from 2000 to 2007 and 432 white controls. Cases were identified in the Danish Extreme Hyperbilirubinemia Database that covers the entire population. Genotypes were obtained through the Danish Neonatal Screening Biobank. Subgroup analysis was done for AB0 incompatible cases.
RESULTS: No association was found between the UGT1A1*28 allele and extreme hyperbilirubinemia. With the common genotype as reference, the odds ratio of extreme hyperbilirubinemia was 0.87 (range, 0.68-1.13) for UGT1A1*28 heterozygotes and 0.77 (range, 0.46-1.27) for homozygotes. Also, no association was found for AB0 incompatible cases.
CONCLUSIONS: The UGT1A1*28 allele was not associated with risk for extreme hyperbilirubinemia in this study.