MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.125.044333

Медицинская библиотека · Journal of the American Heart Association · 2026

TEERAI-Pre: A Multiview Artificial Intelligence Model for Preoperative Assessment of Transcatheter Edge-to-Edge Mitral Valve Repair Using Multiview, Multimodal Echocardiography.

Li Hui, Chen Yida, Zhang Jialin, Guo Ying, Guo Qing, Guo Hongxia, Gong Junsong, Ni Dong, Wang Fang, Xue Wufeng, Duan Fujian

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Transcatheter edge-to-edge mitral valve repair is a key therapeutic option for patients with severe symptomatic mitral regurgitation at high surgical risk. This prospective study aimed to develop a novel end-to-end deep learning model for preoperative artificial intelligence assessment in transcatheter edge-to-edge mitral valve repair (TEERAI-pre) candidates using multiview, multimodal echocardiography.

METHODS

TEERAI-pre, a video vision transformer-based classification model, predicts morphological suitability for transcatheter edge-to-edge mitral valve repair from multiview, multimodal echocardiography. A transformer-based feature-level fusion module was designed in TEERAI-pre to integrate multiview, multimodal features for final prediction. An internal data set of 633 patients (7997 transthoracic echocardiographic videos; 766 pulsed-wave Doppler images) was split for 5-fold cross-validation. An external data set of 150 patients (1735 transthoracic echocardiographic videos; 169 pulsed-wave Doppler images) across 2 hospitals evaluated generalizability. Reference standards were provided by 2 experienced valvular cardiologists per international guidelines.

RESULTS

On the internal data set, TEERAI-pre achieved 75.0% accuracy (95% CI, 71.7%-78.4%) for classifying red (unsuitable), yellow (challenging), and green (ideal) zones, with 77.1% precision, 75.5% recall, and 76.2% F1 score. External validation yielded 73.3% accuracy, 74.0% precision, and 74.0% recall. Multiview multimodal integration improved performance. Binary classification (red versus green) showed TEERAI-pre matched senior experts and outperformed intermediate/junior echocardiologists. Feature-level fusion outperformed output-level fusion and single-view model. Backbone selection and calibration analysis confirmed robust performance.

CONCLUSIONS

TEERAI-pre demonstrates strong performance in transcatheter edge-to-edge mitral valve repair preoperative assessment using transthoracic echocardiographic videos and images, supporting more accurate patient selection and enhancing clinical workflow efficiency.

REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT05508438.

Для цитирования: Li Hui, Chen Yida, Zhang Jialin, Guo Ying, Guo Qing, Guo Hongxia, Gong Junsong, Ni Dong, Wang Fang, Xue Wufeng, Duan Fujian. TEERAI-Pre: A Multiview Artificial Intelligence Model for Preoperative Assessment of Transcatheter Edge-to-Edge Mitral Valve Repair Using Multiview, Multimodal Echocardiography.. Journal of the American Heart Association. 2026. DOI: 10.1161/jaha.125.044333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.