MedElevator Войти в исследования
← Поиск публикаций
JACC. Cardiovascular interventions · 2026

Long-Term Clinical and Hemodynamic Outcomes of Transcatheter Mitral Valve Replacement.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Groshenry Nicolas, Suc Gaspard, Mesnier Jules, Delhomme Clemence, Cailliau Audrey, Brochet Eric, Ducrocq Gregory, Farnoud Reza, Bleuze Linda, Himbert Dominique, Haviari Skerdi, Iung Bernard, Urena Marina

Аннотация

BACKGROUND: Long-term outcomes of transcatheter mitral valve replacement (TMVR) with balloon-expandable aortic prostheses remain uncertain.

OBJECTIVES: The aim of this study was to evaluate long-term clinical and hemodynamic outcomes after TMVR.

METHODS: All patients undergoing TMVR at the authors' center were included. Balloon-expandable transcatheter heart valves were implanted in all cases, usually using a trans-septal approach. The primary outcome was a composite of death or mitral reintervention (surgical or transcatheter replacement or transplantation). Secondary outcomes included mortality, hemodynamic changes, recurrent mitral regurgitation, structural valve deterioration (SVD), and TMVR failure.

RESULTS: A total of 200 patients underwent TMVR: 60.5% (121 of 200) valve-in-valve, 22.5% (45 of 200) valve-in-ring, and 17% (34 of 200) valve-in-mitral annular calcification. The median age was 70 years (Q1-Q3: 52-80 years), and 67% were women (134 of 200). Median follow-up was 3.2 years (Q1-Q3: 1.2-6.8 years). Freedom from death or reintervention at 1, 5, and 8 years was 82% (95% CI: 77%-88%), 48% (95% CI: 40%-56%), and 20% (95% CI: 11%-29%), respectively, with worse outcomes in valve-in-ring and valve-in-mitral annular calcification compared with valve-in-valve (P < 0.01). Mean gradient increased slightly over time (+0.25 ± 0.07 mm Hg/y; P < 0.01), with a modest decrease in effective orifice area (-0.04 cm2/y; P < 0.01). Significant recurrent mitral regurgitation occurred in 5.5% of patients (11 of 200). Seven percent (14 of 200) developed severe SVD after 5.3 (Q1-Q3: 3.5-7.4 years), and 10% (20 of 200) developed TMVR failure after 4.4 (Q1-Q3: 1.8-6.7 years).

CONCLUSIONS: TMVR with balloon-expandable aortic prostheses provides favorable long-term outcomes and acceptable durability, with low rates of severe SVD and valve failure.

Предметные рубрики MeSH