BMC pulmonary medicine · 2024

PaCO2 is nonlinearly associated with NIV failure in patients with hypoxemic respiratory failure.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xu Xiaoping, Ma Mengyi, Min Yiwei, Hu Wenhui, Bai Linfu, Duan Jun

Аннотация

OBJECTIVE: To explore the association between PaCO2 and noninvasive ventilation (NIV) failure in patients with hypoxemic respiratory failure.

METHODS: A retrospective study was performed in a respiratory ICU of a teaching hospital. Patients admitted to ICU between 2011 and 2019 were screened. We enrolled the patients with hypoxemic respiratory failure. However, patients who used NIV due to acute-on-chronic respiratory failure or heart failure were excluded. Data before the use of NIV were collected. Requirement of intubation was defined as NIV failure.

RESULTS: A total of 1029 patients were enrolled in final analysis. The rate of NIV failure was 45% (461/1029). A nonlinear relationship between PaCO2 and NIV failure was found by restricted cubic splines (p = 0.03). The inflection point was 32 mmHg. The rate of NIV failure was 42% (224/535) in patients with PaCO2 >32 mmHg. However, it increased to 48% (237/494) in those with PaCO2 ≤ 32 mmHg. The crude and adjusted hazard ratio (HR) for NIV failure was 1.36 (95%CI:1.13-1.64) and 1.23(1.01-1.49), respectively, if the patients with PaCO2 >32 mmHg were set as reference. In patients with PaCO2 ≤ 32 mmHg, one unit increment of PaCO2 was associated with 5% reduction of NIV failure. However, it did not associate with NIV failure in patients with PaCO2 >32 mmHg.

CONCLUSIONS: PaCO2 and NIV failure was nonlinear relationship. The inflection point was 32 mmHg. Below the inflection point, lower PaCO2 was associated with higher NIV failure. However, it did not associate with NIV failure above this point.