CMR T1 and T2 mapping and extracellular volume quantification in systolic phase produces superior image quality with less motion artifacts and equal mapping values compared to conventional diastolic mapping.

Federico Johanna, Syväranta Suvi, Holmström Miia, Lommi Jyri, Suihko Satu, Peltomaa Ritva, Koivuniemi Riitta, Leirisalo-Repo Marjatta, Peltonen Juha, Kaasalainen Touko, Vaara Satu

СтатьяПеревод в очереди

Аннотация

AIM: This study investigated whether systolic phase imaging improves cardiac magnetic resonance (CMR) mapping by reducing artifacts compared with diastolic phase analyses. We evaluated T1 and T2 relaxation times and extracellular volume (ECV) in healthy individuals, early rheumatoid arthritis (ERA), and aortic stenosis (AS) patients.

MATERIALS AND

METHODS

A total of 114 participants (54 healthy adults, 30 ERA and 30 AS patients) underwent 1.5 T CMR with T1, T2, and ECV mapping in both diastolic and systolic phases. Imaging artifacts were categorized as minor or major, and inter-observer agreement was assessed for image quality and reproducibility.

RESULTS

Systolic phase mapping significantly reduced minor imaging artifacts across all cohorts (14% vs 5%, p < 0.001 for T1; 5% vs 2%, p < 0.001 for T2 in healthy cohort), particularly in participants with thinner myocardium. Inter-observer agreement assessed in the ERA cohort was excellent, with higher intraclass correlation coefficients (ICC) for systolic than diastolic mapping, particularly for T2 (0.975 vs 0.867) and ECV (0.951 vs 0.891). Systolic mapping yielded comparable T1 and T2 relaxation times across all cohorts.

CONCLUSIONS

Systolic mapping provides comparable T1, T2, and ECV values to diastolic mapping, while reducing artifacts, supporting its clinical applicability across diverse patient profiles.

Для цитирования: Federico Johanna, Syväranta Suvi, Holmström Miia, Lommi Jyri, Suihko Satu, Peltomaa Ritva, Koivuniemi Riitta, Leirisalo-Repo Marjatta, Peltonen Juha, Kaasalainen Touko, Vaara Satu. CMR T1 and T2 mapping and extracellular volume quantification in systolic phase produces superior image quality with less motion artifacts and equal mapping values compared to conventional diastolic mapping.. Magma (New York, N.Y.). 2026. DOI: 10.1007/s10334-026-01353-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.