MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.17428

Медицинская библиотека · Acta ophthalmologica · 2024

Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx-DR.

Grzybowski Andrzej, Peeters Freya, Barão Rafael Correia, Brona Piotr, Rommes Stef, Krzywicki Tomasz, Stalmans Ingeborg, Jacob Julie

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare two artificial intelligence (AI)-based Automated Diabetic Retinopathy Image Assessment (ARIA) softwares in terms of concordance with specialist human graders and referable diabetic retinopathy (DR) diagnostic capacity.

METHODS

Retrospective comparative study including 750 consecutive diabetes mellitus patients imaged for non-mydriatic fundus photographs. For each patient four images (45 degrees field of view) were captured, centered on the optic disc and macula. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more), referable DR (RDR (more than mild DR)), or sight-threatening DR (severe NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]). IDx-DR and MONA DR output was compared with manual grading and with each other.

RESULTS

Total sample size was 750 patients, of which 55 were excluded due to ungradable images. Out of the remaining 695 patients 522 (75%) were considered as having no DR by manual consensus grading, and 106 (15%) as having RDR. Agreement between raters varied between moderate to substantial. IDx-DR showed moderate agreement with human grading (k = 0.4285) while MONA DR had substantial agreement (k = 0.6797). Out of 106 patients with a ground truth of RDR, IDx-DR identified 105 and MONA DR identified 99. The sensitivity and specificity rates for RDR detection of IDx-DR were 99.1 and 71.5% compared with MONA DR of 93.4 and 89.3% respectively. Of note, both ARIAs had 100% sensitivity for the detection of STDR.

CONCLUSION

Both ARIAs performed well in this study population, both with sensitivity for RDR screening over 90%, with IDx-DR showing higher sensitivity and MONA DR higher specificity. MONA DR showed superior agreement with human certified graders.

Для цитирования: Grzybowski Andrzej, Peeters Freya, Barão Rafael Correia, Brona Piotr, Rommes Stef, Krzywicki Tomasz, Stalmans Ingeborg, Jacob Julie. Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx-DR.. Acta ophthalmologica. 2024. DOI: 10.1111/aos.17428.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.