DOI 10.1097/mao.0000000000004753

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2025

Spectrotemporal Assessment of Pulse-synchronous Sound in the Outer Ear Canal in Patients With Pulsatile Tinnitus.

Metselaar Mick, van Immerzeel Teun, Toll Martijn S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe and investigate the diagnostic value of a spectrotemporal assessment of sound recorded from the outer ear canal in patients with pulsatile tinnitus.

STUDY

DESIGN

A small microphone was placed in the outer ear to record sound. Meanwhile, a pulsoximeter recorded heartbeats. Both signals were visually assessed for pulse-synchronicity.

SETTING

Tertiary referral center.

PATIENTS: One hundred fifteen patients presenting with pulsatile tinnitus (PT) who had a normally aerated middle ear and in whom a radiologic explanation was identified or excluded with CT-angiography (CTA) and/or neuroangiography (NA).

INTERVENTION: Diagnostic.

MAIN OUTCOME MEASURE: The diagnostic value of our method, including sensitivity and specificity.

RESULTS

Sixty-nine (60%) of all patients had an extra pulse-synchronous sound in the spectrogram at one or both ears that was clearly visible in 60 and somewhat more difficult to recognize in 9 patients. In 86 (75%) of all patients, we found a vascular cause of PT. Two patients with a pulse-synchronous sound at one or both ears had no vascular explanation on both CTA and NA (false-positive). In 19 patients, we did not see a pulse-synchronous spectrogram in either ear, although radiologic workup showed a vascular cause (false-negative). Five of them had an arterial cause of PT, in 14, a venous cause was found.

CONCLUSIONS

Transcanal sound recording in patients presenting with PT provides diagnostic information on the likelihood of a vascular origin, although sensitivity is limited. This noninvasive method can help the clinician to decide on the appropriate diagnostic workup, avoiding unnecessary burden, risk, and costs of diagnostic imaging, including NA.

Для цитирования: Metselaar Mick, van Immerzeel Teun, Toll Martijn S. Spectrotemporal Assessment of Pulse-synchronous Sound in the Outer Ear Canal in Patients With Pulsatile Tinnitus.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2025. DOI: 10.1097/mao.0000000000004753.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.