DOI 10.1016/j.pdpdt.2024.104237
Anterior segment optical coherence tomography for superficial keratectomy.
Аннотация
PURPOSE: To report the use of anterior segment optical coherence tomography (AS-OCT) for superficial keratectomy (SK) in anterior corneal opacity.
METHODS
The characteristics of 43 eyes (39 patients) with various lesions responsible for anterior corneal opacity were included in this retrospective non-comparative study. AS-OCT was performed on all eyes before surgery. The thickness of corneal opacity and the underlying healthy stroma were measured. SK was performed on each individual.
RESULTS
Four types of anterior corneal opacity were evaluated, including corneal degeneration (26/43), Reis-Bücklers corneal dystrophy (8/43), alkali burn (1/43) and corneal tumors (8/43). Based on AS-OCT images, all eyes showed abnormal hyper-reflective signals in the superficial cornea to less than one-third of the normal corneal thickness in the deepest corneal opacity. All 43 eyes underwent an SK procedure. In addition, 1 eye with alkali burns and 7 eyes with corneal tumors were combined with amniotic membrane transplantation. All eyes restored transparency without significant complications.
CONCLUSION
AS-OCT is a valuable method for objective preoperative and noninvasive assessments of anterior corneal opacities and is useful for guiding SK.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.