MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.129.3.676

Медицинская библиотека · Chest · 2006

Clinical effects of heliox administration for acute bronchiolitis in young infants.

Cambonie Gilles, Milési Christophe, Fournier-Favre Sébastien, Counil François, Jaber Samir, Picaud Jean-Charles, Matecki Stefan

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To assess the effect of heliox, a helium-oxygen mixture, on respiratory distress symptoms in young infants.

DESIGN

Prospective, randomized, double-blind study.

SETTING

Pediatric ICU (PICU) of a university hospital.

PATIENTS: Twenty infants, all < 3 months old, admitted to the PICU with moderate-to-severe acute respiratory syncytial virus bronchiolitis.

INTERVENTIONS: All infants were randomly and blindly assigned to inhale either heliox or an air-oxygen mixture (airox) for 1 h under an oxyhood.

MEASUREMENTS AND

RESULTS

After 1 h, the respiratory distress score was significantly lower in the heliox group compared with the airox group (3.05 vs 5.5, p < 0.01), with a significant reduction in accessory muscles use (p < 0.05) and expiratory wheezing (p < 0.01). In contrast, inspiratory breath sounds and cyanosis did not significantly differ between groups. The ex-premature infants of the heliox group had a higher respiratory distress score at baseline compared with the term infants of this group (5.8 vs 5.2, p < 0.05) and a comparable decrease in the score at 60 min.

CONCLUSIONS

In young infants, even those born prematurely, heliox breathing induced a rapid reduction in accessory muscles use and expiratory wheezing. Further studies are needed to confirm the decreased respiratory muscle work of breathing during heliox inhalation in this population.

Для цитирования: Cambonie Gilles, Milési Christophe, Fournier-Favre Sébastien, Counil François, Jaber Samir, Picaud Jean-Charles, Matecki Stefan. Clinical effects of heliox administration for acute bronchiolitis in young infants.. Chest. 2006. DOI: 10.1378/chest.129.3.676.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.