Journal of clinical microbiology · 2026
Multisite clinical evaluation of the iFAST rapid antimicrobial susceptibility test direct from positive blood cultures containing gram-negative organisms.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hornsey Michael, Taylor Isobel, King Toby, Brown Zoe, Cançado Daniel Nathan Tomás, Judd Katie, Kuszynski Eleanor, Lines Rowena, Lyon Rhiannon, Wang Xiang, Lloyd Allyson, Impey Robert, Ashworth Gareth, Gatenby Maria, MacGowan Alasdair, Albur Mahableshwar, Noel Alan, Attwood Marie, Griffin Pippa, Brennan Cliodna, Oubridge Brock Freddie, Stewart Jane, Alonso-Moreno Estíbaliz, Morgan Hywel, Spencer Daniel
Аннотация
UNLABELLED: iFAST is a label-free rapid antimicrobial susceptibility test (AST) that delivers qualitative results in under 4 h from a positive blood culture bottle. The technique measures changes in the electrical properties of thousands of individual bacteria following exposure to antibiotics. We report the diagnostic accuracy from the first clinical study of the iFASTone rapid AST system in three different centers according to ISO 20776-2:2021. Compared to the reference laboratory broth microdilution method, categorical agreement was 97.8% and 97.2% for the Enterobacterales and non-fermenting gram-negative species, respectively. iFAST specificity and sensitivity for the Enterobacterales were 98.2% and 96.8%, respectively, and 96.9% and 98.4% for the non-fermenting species, exceeding the acceptance criteria (≥95% sensitivity and specificity). Reproducibility was assessed with 12 isolates across 3 sites, in triplicate, on 3 separate days, with different operators at each site. Agreement was 95.7%.
IMPORTANCE: Even short delays in the initiation of antimicrobial therapy in patients with bloodstream infections are associated with increased morbidity and mortality. Consequently, current guidelines recommend initiation of empiric antimicrobial therapy within 1 h of presentation. However, empiric broad-spectrum therapy may not always be appropriate and can contribute to the selection of resistant organisms. Antimicrobial susceptibility testing (AST) is therefore critical for antimicrobial stewardship and the timely selection of targeted therapy, but conventional methods typically require 1 to 2 days to generate results. This study evaluated the diagnostic accuracy of iFAST, a new low-cost, label-free rapid AST using 375 Enterobacterales and non-fermenter isolates tested directly from positive blood cultures, according to ISO-20776-2:2021. Compared with broth microdilution, iFAST demonstrated high sensitivity, specificity, and categorical agreement, with a time to result of less than 4 h. These findings support the implementation of iFAST for same-shift AST results.
IMPORTANCE: Even short delays in the initiation of antimicrobial therapy in patients with bloodstream infections are associated with increased morbidity and mortality. Consequently, current guidelines recommend initiation of empiric antimicrobial therapy within 1 h of presentation. However, empiric broad-spectrum therapy may not always be appropriate and can contribute to the selection of resistant organisms. Antimicrobial susceptibility testing (AST) is therefore critical for antimicrobial stewardship and the timely selection of targeted therapy, but conventional methods typically require 1 to 2 days to generate results. This study evaluated the diagnostic accuracy of iFAST, a new low-cost, label-free rapid AST using 375 Enterobacterales and non-fermenter isolates tested directly from positive blood cultures, according to ISO-20776-2:2021. Compared with broth microdilution, iFAST demonstrated high sensitivity, specificity, and categorical agreement, with a time to result of less than 4 h. These findings support the implementation of iFAST for same-shift AST results.