MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.26582

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2016

Prognostic Importance of Diastolic Dysfunction in Relation to Post Procedural Aortic Insufficiency in Patients Undergoing Transcatheter Aortic Valve Replacement.

Kampaktsis Polydoros N, Bang Casper N, Chiu Wong S, Skubas Nikolaos J, Singh Harsimran, Voudris Konstantinos, Baduashvili Amiran, Pastella Kalliopi, Swaminathan Rajesh V, Kaple Ryan K, Minutello Robert M, Feldman Dmitriy N, Kim Luke, Hriljac Ingrid, Lin Fay, Bergman Geoffrey S, Salemi Arash, Devereux Richard B

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

We sought to examine whether baseline diastolic dysfunction (DD) is associated with increased mortality in patients who develop aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR).

BACKGROUND

Significant post-TAVR AI is associated with increased mortality, likely secondary to adverse hemodynamics secondary to volume overload and decreased LV compliance from chronic pressure overload. However, the effect of baseline DD on outcomes of patients with post-TAVR AI has not been studied.

METHODS

A total of 195 patients undergoing TAVR were included in the study. Patients with moderate-to-severe mitral stenosis, prior mitral valve replacement or atrial fibrillation were excluded. DD was classified at baseline by a 2-step approach as recommended by the American Society of Echocardiography while AI was evaluated 30 days post-TAVR. Follow up data up to 2 years post-TAVR was used in survival analysis.

RESULTS

Patients with severe baseline DD who developed ≥mild post-TAVR AI had increased mortality compared to all other patients (HR = 3.89, CI: 1.76-8.6, P = 0.001), which remained significant after adjusting for post-TAVR AI, pre-TAVR AI, baseline mitral regurgitation, ejection fraction, pulmonary artery pressure, creatinine clearance and history of stroke.

CONCLUSIONS

Even mild post-TAVR AI may have a negative impact on outcomes of patients with underlying severe DD. © 2016 Wiley Periodicals, Inc.

Для цитирования: Kampaktsis Polydoros N, Bang Casper N, Chiu Wong S, Skubas Nikolaos J, Singh Harsimran, Voudris Konstantinos, Baduashvili Amiran, Pastella Kalliopi, Swaminathan Rajesh V, Kaple Ryan K, Minutello Robert M, Feldman Dmitriy N, Kim Luke, Hriljac Ingrid, Lin Fay, Bergman Geoffrey S, Salemi Arash, Devereux Richard B. Prognostic Importance of Diastolic Dysfunction in Relation to Post Procedural Aortic Insufficiency in Patients Undergoing Transcatheter Aortic Valve Replacement.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26582.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.