MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2025.40.e168

Медицинская библиотека · Journal of Korean medical science · 2025

A Patch-Type Electrocardiography Is Superior to Holter Monitoring for Detecting Paroxysmal Cardiac Arrhythmias.

Kim Yun Gi, Choi Jong-Il, Oh Il-Young, Jeong Joo Hee, Lee Hyoung Seok, Choi Yun Young, Lee Ji Hyun, Cho Youngjin, Shim Jaemin, Son Ho Sung, Kim Young-Hoon

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patch-electrocardiography (ECG) enables prolonged ECG monitoring beyond 24 hours. However, diagnostic yield between patch-ECG and Holter monitoring needs further validation. We aimed to compare diagnostic capabilities of 14-day patch-ECG and one day Holter monitoring to detect cardiac arrhythmias.

METHODS

Patients with suspected cardiac arrhythmias but could not be diagnosed by 12-lead ECG were enrolled from two tertiary centers. Patch-ECG and Holter monitoring was attached simultaneously in enrolled patients. Primary endpoint was detection of major arrhythmias which was defined as atrial fibrillation (AF), atrial tachycardia, atrial flutter, paroxysmal supraventricular tachycardia (PSVT), ventricular tachycardia, 2nd or 3rd degree atrioventricular block, sick pause (> 2 seconds of pause), sick sinus syndrome, tachycardia-bradycardia syndrome, and Wolff-Parkinson-White syndrome.

RESULTS

A total of 147 patients were analyzed. Major arrhythmias were detected in 75.5% and 48.3% in patch-ECG and Holter monitoring, respectively (P < 0.001). Detection rate between the first day of patch-ECG and Holter monitoring was identical. Detection rate for AF was significantly higher in patch-ECG (23.8% vs. 11.6%; P < 0.001). Substantial proportion of AF events were detected in the first day of monitoring (42.9%) but diagnosis rate increased steadily between day 2-14 of monitoring. Detection rate of supraventricular tachycardia (atrial tachycardia or PSVT), ventricular tachycardia, and brady-arrhythmias was higher in the patch-ECG. Four patients had to detach their patch-ECG due to skin side effects.

CONCLUSION

Patch-ECG has higher diagnostic capabilities compared to Holter monitoring for diagnosis of various cardiac arrhythmias.

Для цитирования: Kim Yun Gi, Choi Jong-Il, Oh Il-Young, Jeong Joo Hee, Lee Hyoung Seok, Choi Yun Young, Lee Ji Hyun, Cho Youngjin, Shim Jaemin, Son Ho Sung, Kim Young-Hoon. A Patch-Type Electrocardiography Is Superior to Holter Monitoring for Detecting Paroxysmal Cardiac Arrhythmias.. Journal of Korean medical science. 2025. DOI: 10.3346/jkms.2025.40.e168.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.