MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12985-021-01510-6

Медицинская библиотека · Virology journal · 2021

A multiplex real-time PCR quantitation of human herpesvirus-6, 7, 8 viruses: application in blood transfusions.

Zheng Yi, Zhao Youyun, Wang Yefu, Rao Jun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In recent years, fluorescent quantitative polymerase chain reaction assays for detecting viral DNA are in widespread use throughout the world. However, considering the wide distribution of new herpesvirus among the population, we constructed a method to detect HHV-6, 7, and 8 simultaneously.

METHODS

The blood samples of 74 blood donors and 45 pityriasis rosea patients were collected. The recombinant plasmids containing U67, U36, and orf65 were constructed to optimize the PCR reaction system. The forward and reverse primers and probe sequences of HHV-6 were as follows: TAAATATCGATGCCGCTCTG, ACGTTCTAGCCATCTTCTTTG, CGCAAACGACAAAGCCA. The forward and reverse primers and probe sequences of HHV-7 were as follows: TTAGACATCTTACACGACAGC, CAGCTTTTCGAACTTGTCAC, TTCATCGGGTACGTCCA. The forward and reverse primers and probe sequences of HHV-8 were as follows: GCGACATATTTCCCTGATCC, CCAACTTTAAGGTGAGAGACC, CATGCGAGCCACCAG. Through the detection of housekeeping genes, DNA sequencing, and optimization of the PCR reaction system, the triple fluorescent quantitative PCR detection system was constructed. Blood samples of blood transfusion staff and pityriasis rosea patients were detected.

RESULTS

The correlations of HHV-6, 7, and 8 between single and multiplex PCR are 0.980, 0.987, 0.965, respectively. In 74 blood donor samples, 16.2% of HHV-6 and 55% of HHV-7 were positive (viral load > 3 log10 copies/ml) according to multiplex real-time PCR. In 45 patients suspected of pityriasis rosea (PR) infection, 40% HHV-6, 73.3% positive cases are found.

CONCLUSION

With the safety of blood transfusion being a major concern of the public, this method will show good specificity and sensitivity in blood transfusion screening.

Для цитирования: Zheng Yi, Zhao Youyun, Wang Yefu, Rao Jun. A multiplex real-time PCR quantitation of human herpesvirus-6, 7, 8 viruses: application in blood transfusions.. Virology journal. 2021. DOI: 10.1186/s12985-021-01510-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.