MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2023.4.jns23637

Медицинская библиотека · Journal of neurosurgery · 2023

Custom shaping of distal access catheter for navigation of microcatheter into inferolateral and meningohypophyseal trunk feeders.

Hirano Yudai, Shojima Masaaki, Uno Takeshi, Koizumi Satoshi, Oyama Yuta, Indo Masahiro, Saito Akira, Oya Soichi, Saito Nobuhito, Shin Masahiro

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Navigating a microcatheter to tiny feeding arteries such as the inferolateral trunk (ILT) and meningohypophyseal trunk (MHT) of the internal carotid artery (ICA) is technically challenging because of the anatomical features of steep angulation, small diameter, and significant caliber difference from the ICA. To guide the microcatheter to these ICA side branch feeders, the authors thought that a custom shaping of the intermediate catheter would be helpful to determine the direction of the microcatheter and strongly back it up. The aim of this study was to report the detailed methodology and clinical outcomes of patients who had undergone the embolization of ILT and MHT feeders using this method.

METHODS

This was a retrospective study of consecutive patients with intracranial tumors and dural arteriovenous fistulas (DAVFs) who had undergone endovascular embolization. The details of the embolization procedures were examined, especially the technique of guiding a low-profile microcatheter supported by the thermoformed intermediate catheter. The authors assessed the patient background, procedural outcomes, and postoperative complications.

RESULTS

Between October 2013 and June 2022, 43 patients with intracranial tumors and 45 with DAVFs underwent embolization at the authors' institutions. Among these cases, embolization of the ICA side branch feeder was attempted in 10 intracranial tumors and 2 DAVFs. Of these 12 patients, the microcatheter was guided deep enough for successful embolization in 11 cases (92%). Two asymptomatic arteriovenous fistulas were complicated during guidewire manipulation deep in the feeder. Yet, both disappeared completely after glue injection into the feeding artery. No spasm or dissection of the parent artery occurred during the procedure. Postoperative radiological evaluation showed no intracranial hematoma or symptomatic cerebral infarction. One patient (9%) developed permanent postoperative cranial neuropathy that gradually improved after embolization.

CONCLUSIONS

This study revealed that custom shaping of distal access catheters is an effective technique that enabled the embolization of ILT and MHT feeders with a success rate of more than 90%.

Для цитирования: Hirano Yudai, Shojima Masaaki, Uno Takeshi, Koizumi Satoshi, Oyama Yuta, Indo Masahiro, Saito Akira, Oya Soichi, Saito Nobuhito, Shin Masahiro. Custom shaping of distal access catheter for navigation of microcatheter into inferolateral and meningohypophyseal trunk feeders.. Journal of neurosurgery. 2023. DOI: 10.3171/2023.4.jns23637.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.