DOI 10.1097/ico.0000000000003462
Artificial Endothelial Layer Implantation After Multiple Failed Keratoplasties.
Аннотация
PURPOSE: Presenting the first case of noncellular corneal endothelial substitute after multiple failed penetrating keratoplasty (PK) and lamellar endothelial keratoplasty.
METHODS
Our case presented with pseudophakic bullous keratopathy after a history of 2 rejected PKs and 1 rejected Descemet stripping automated endothelial keratoplasty. We implanted an artificial endothelial layer.
RESULTS
The implant remained fully attached for a follow-up period of 12 months, and central corneal thickness decreased significantly. The patient reported improvement in her subjective vision, although ocular comorbidities limited the visual potential.
CONCLUSIONS
This new device could serve as an alternative to lamellar endothelial corneal transplantation in cases where tissue rejection has occurred and is highly likely to recur. The technique is simple, and the deswelling effect on the cornea persisted, although the visual results require further validation in patients with a higher visual potential.