Dual-layered stents reduce cerebral embolism compared with first-generation stents during carotid stenting of high lipid core plaque lesions.

Nakagawa Ichiro, Kotsugi Masashi, Yokoyama Shohei, Maeoka Ryosuke, Furuta Takanori, Tanaka Haku, Takeshima Yasuhiro, Matsuda Ryosuke, Yamada Shuichi, Nakase Hiroyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Periprocedural lipid core plaque (LCP) has been detected in carotid arteries assessed by catheter-based near-infrared spectroscopy (NIRS). High LCP is associated with cerebral embolism after carotid artery stenting (CAS) using a first-generation stent. We aimed to evaluate whether dual-layered stents reduce embolic infarcts in patients with high LCP and change of lipid signal as assessed by NIRS during CAS.

METHODS

Participants comprised 210 consecutive patients undergoing CAS. The study was divided into two distinct periods, with first-generation closed-cell stents used in the earlier period and dual-layered stents used in the later period. NIRS was performed at baseline, after stent implantation, and after balloon post-dilatation to analyze maximal lipid core burden index at minimal luminal area (max-LCBIMLA).

RESULTS

The ipsilateral cerebral embolism rate was significantly lower with dual-layered stents (9%) than with first-generation stents (33%, p<0.001), particularly with highly lipidic lesions (12% vs 60%, p<0.001). On multivariate logistic regression analysis, high LCP and first-generation stent usage were factors related to ipsilateral cerebral embolism (both p<0.001; OR 8.28 (95% CI 3.49 to 19.64) and OR 8.07 (95% CI 2.33 to 27.93), respectively). Max-LCBIMLA decreased significantly after stenting in both groups (both p<0.01) and max-LCBIMLA after balloon post-dilatation was significantly lower with dual-layered stents (22.4±65.6) than with first-generation stents (124.2±208.2; p=0.006).

CONCLUSIONS

Dual-layered stents reduce embolic infarcts in patients with highly lipidic plaque lesions as assessed by NIRS who undergo CAS. Dual-layered stents significantly reduced NIRS-derived lipid signals after stenting.

Для цитирования: Nakagawa Ichiro, Kotsugi Masashi, Yokoyama Shohei, Maeoka Ryosuke, Furuta Takanori, Tanaka Haku, Takeshima Yasuhiro, Matsuda Ryosuke, Yamada Shuichi, Nakase Hiroyuki. Dual-layered stents reduce cerebral embolism compared with first-generation stents during carotid stenting of high lipid core plaque lesions.. Journal of neurointerventional surgery. 2023. DOI: 10.1136/jnis-2023-020106.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.