The Effect of The Changes in Cylinder Power and Axis of Toric Soft Contact Lenses on Vision of Astigmatic Subjects.
Аннотация
PURPOSE: To investigate the effect of higher cylindrical power and axis misalignment of toric SCL in mild and moderate astigmatism on visual acuity, contrast sensitivity, visual satisfaction, and vision acceptability.
METHODS
20 astigmatic participants underwent randomized experimental trial for the following conditions on different days: full cylinder power, higher cylindrical power by 0.5D, and higher cylindrical power by 1.0DC. Axis was also misaligned by -10 and +10degree for each cylinder power alteration. Baseline and outcome variables were assessed using: Snellen chart for visual acuity, Pelli-Robson Chart for contrast sensitivity, and VAS scale for visual clarity, satisfaction and vision acceptability.
RESULTS
Overcorrecting cylinder power resulted in significant effect (p<0.05) on all variables. Overall, higher cylindrical power by 1.0DC had stronger statistical evidence (p<0.01) than 0.5DC. There was no significant difference between the mild and moderate astigmatism groups, except for the visual acuity when higher cylindrical power by 0.5 D was implemented. Misalignment by both +10° and -10° had a significant effect on all variables, except contrast sensitivity.
CONCLUSION
Toric SCL with higher cylindrical power by 0.5DC and 1.0DC as well as misalignment of 10° had a significant effect on visual acuity, contrast sensitivity, clarity, satisfaction, and vision acceptability in patients with mild to moderate astigmatism.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.