Absent Stapedial Tendon: Imaging Features of an Underrecognized Entity : Clinical Neuroradiology.

Burkett Brian J, Oien Michael P, Benson John C, Nassiri Ashley M, Carlson Matthew L, Lane John I

СтатьяПеревод в очереди

Аннотация

PURPOSE: Congenital absence of the stapedial tendon is a rare entity with characteristic imaging findings, which can go unrecognized due the scarcity of the diagnosis and limited previous description in the imaging literature. We aim to characterize the imaging features of this entity.

METHODS

A series of 9 cases with surgical confirmation of stapedial tendon absence were retrospectively reviewed and the most common abnormalities on high resolution computed tomography (CT) of the temporal bone described.

RESULTS

Congenital fixation of the stapes footplate was present in nearly all cases of stapedial tendon absence (n = 8, 89%), a clinically important association because the stapes footplate abnormality was not detectable on preoperative CT. Absence or hypoplasia of the pyramidal eminence and aperture was identified in almost all cases (n = 8, 89%), which may be the sole imaging finding to suggest stapedial tendon absence and associated stapes footplate fixation prior to surgery.

CONCLUSION

The most reliable indicator of stapedial muscle absence on temporal bone CT is the absence or hypoplasia of the pyramidal eminence and aperture. Importantly, most patients had congenital stapes footplate fixation confirmed intraoperatively with a normal stapes footplate on CT, meaning the pyramidal eminence/aperture abnormality was the only preoperative imaging finding that could have suggested the footplate fixation.

Для цитирования: Burkett Brian J, Oien Michael P, Benson John C, Nassiri Ashley M, Carlson Matthew L, Lane John I. Absent Stapedial Tendon: Imaging Features of an Underrecognized Entity : Clinical Neuroradiology.. Clinical neuroradiology. 2023. DOI: 10.1007/s00062-022-01251-1.