MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezaf034

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2025

Valve-sparing aortic root replacement for valves with paracommissural fenestrations: which valve will fail?

Kari Fabian A, Czerny Martin, Borger Michael, Misfeld Martin, Rylski Bartosz, Zimmer Emmanuel, Siepe Matthias, Hagl Christian, Detter Christian, Petersen Johannes, Richardt Doreen, Ensminger Stephan, Werner Paul, Andreas Martin, Peterss Sven, Pichlmaier Maximilian, Mueller Christoph S

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To define morphologic risk constellations during valve-sparing aortic root replacement (VSARR) for aortic valves with paracommissural fenestrations.

METHODS

Patients from the multicentre prospective intention-to-treat VSARR-registry German Aortic Root Repair Registry (GEARR) were screened for paracommissural cusp fenestrations. We studied a combined end-point of residual aortic regurgitation (rAR) on post-cardiopulmonary bypass (CPB) transesophageal echocardiography (TEE), mid-term progress of rAR (transthoracic echocardiography) and aortic valve replacement for AR.

RESULTS

Of a total of 762 registry patients (operated 2016-2024), 145 were identified with ≥1 paracommissural cusp fenestration. Eighteen patients (12%) were not treated as planned but underwent composite valved graft (CVG) implantation. Mean follow-up time was 3 years. Upon post-CPB TEE, rAR grade 1 or 2 were present in 44 (33%) and 3 (2%) patients. 50% of patients with fenestrations in more than one cusp showed early progression of rAR. At 3 years, freedom from the combined end-point was 78% (99% CI 74-79%) for the complete study cohort. Patients with a maximum free margin length difference of <5 mm, reflecting balanced root anatomy with respect to sinus and cusp sizes, had a significantly better outcome than those with ≥5 mm: at 3 years, freedom from the combined end-point was 86% (99% CI 80-91%) vs 41% (99% CI 38-46%, P = 0.011). Outcome was worst for patients with cusp prolapse and a free margin length difference of >5 mm (30% vs 70%, P = 0.018).

CONCLUSIONS

Fenestrations in more than one cusp, inhomogeneities of cusp-free margin lengths, and additional prolapse are associated with inferior outcome after VSARR for valves with paracommissural fenestrations.

CLINICAL TRIAL REGISTRATION NUMBER: DRKS00007872.

Для цитирования: Kari Fabian A, Czerny Martin, Borger Michael, Misfeld Martin, Rylski Bartosz, Zimmer Emmanuel, Siepe Matthias, Hagl Christian, Detter Christian, Petersen Johannes, Richardt Doreen, Ensminger Stephan, Werner Paul, Andreas Martin, Peterss Sven, Pichlmaier Maximilian, Mueller Christoph S. Valve-sparing aortic root replacement for valves with paracommissural fenestrations: which valve will fail?. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2025. DOI: 10.1093/ejcts/ezaf034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.