The Gait Disorientation Test: A New Method for Screening Adults With Dizziness and Imbalance.

Grove Colin R, Heiderscheit Bryan C, Pyle G Mark, Loyd Brian J, Whitney Susan L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To develop and evaluate a new method for identifying gait disorientation due to vestibular dysfunction.

DESIGN

The gait disorientation test (GDT) involves a timed comparison of the ability to walk 6.096 m with eyes open versus eyes closed. In this prospective study, participants were grouped based on vestibular function. All participants completed a clinical examination, self-report- and performance-based measures relevant to vestibular rehabilitation, and the tasks for the GDT. Vestibular-impaired participants underwent the criterion standard, videonystagmography and/or rotational chair testing.

SETTING

Ambulatory clinic, tertiary referral center.

PARTICIPANTS

Participants (N=40) (20 vestibular-impaired, 30 women, 49.9±16.1years old) were enrolled from a convenience/referral sample of 52 adults.

MAIN OUTCOME AND MEASURE(S): We determined test-retest reliability using the intraclass correlation coefficient model 3,1; calculated the minimal detectable change (MDC); examined concurrent validity through Spearman correlation coefficients; assessed criterion validity with the area under the curve (AUC) from receiver operator characteristic analysis; and computed the sensitivity, specificity, diagnostic odds ratio (DOR), likelihood ratios for positive (LR+) and negative (LR-) tests, and posttest probabilities of a diagnosis of vestibulopathy. The 95% confidence interval demonstrates measurement uncertainty.

RESULTS

Test-retest reliability was 0.887 (0.815, 0.932). The MDC was 3.7 seconds. Correlations with other measures ranged from 0.59 (0.34, 0.76) to -0.85 (-0.92, -0.74). The AUC was 0.910 (0.822, 0.998), using a threshold of 4.5 seconds. The sensitivity and specificity were 0.75 (0.51, 0.91) and 0.95 (0.75, 1), respectively. The DOR=57 (6, 541.47), LR+ =15 (2.18, 103.0), and LR- =0.26 (0.12, 0.9). Positive posttest probabilities were 89%-94%.

CONCLUSIONS AND RELEVANCE: The GDT has good reliability, excellent discriminative ability, strong convergent validity, and promising clinical utility.

Для цитирования: Grove Colin R, Heiderscheit Bryan C, Pyle G Mark, Loyd Brian J, Whitney Susan L. The Gait Disorientation Test: A New Method for Screening Adults With Dizziness and Imbalance.. Archives of physical medicine and rehabilitation. 2020. DOI: 10.1016/j.apmr.2020.11.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.