m+Medelevator.RU
← Поиск публикаций
Circulation. Cardiovascular interventions · 2018

Transcatheter Mitral Valve Replacement in Patients With Previous Aortic Valve Replacement.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cheung Anson, Webb John, Schaefer Ulrich, Moss Robert, Deuschl Florian G, Conradi Lenard, Denti Paolo, Latib Azeem, Kiaii Bob, Bagur Rodrigo, Ferrari Enrico, Moccetti Marco, Biasco Luigi, Blanke Philippe, Ben-Gal Yanai, Banai Shmuel

Аннотация

BACKGROUND: Transcatheter mitral valve replacement (TMVR) may mature to become a therapeutic option for high-risk patients with severe mitral regurgitation (MR), particularly in patients at high or prohibitive surgical risk. MR patients with preexisting aortic valve prosthesis have been excluded from most TMVR trials because of the potential risks of left ventricular outflow tract obstruction or interaction between the TMVR anchoring mechanism and the aortic prosthesis. We describe the procedural and short-term outcomes of transapical TMVR with the Tiara valve in patients experiencing severe symptomatic MR with previous aortic valve replacement (AVR).

METHODS AND RESULTS: Twelve consecutive high surgical risk patients (11 men; mean age, 75±6 years) with aortic valve prosthesis and severe MR underwent TMVR with Tiara valve. Aortic valves were mechanical in 5 and biological in 7 patients, while 1 patient had previously undergone implantation of a transcatheter valve within a failed bioprosthetic surgical valve. Six patients (50%) had undergone redo surgical aortic valve replacement. Clinical characteristics of the group include prior mitral valve repair in 2, prior coronary bypass grafting surgery in 5, chronic atrial fibrillation in 7, renal failure in 9, and pacemaker/cardiac resynchronization device in 9 patients. Mean Society of Thoracic Surgery score and EuroSCORE II were 10.5±4.4 and 12.4±3.7, respectively. Mean baseline left ventricular ejection fraction was 35.5±5.3% (range, 30%-45%). The Tiara valve was implanted uneventfully in all patients. Device migration or left ventricular outflow tract obstruction was not observed. No patient required conversion to open heart surgery or periprocedural hemodynamic support. Procedural success was 100% with no death, MI, stroke, major bleeding, or access site complications at 30 days. MR was eliminated in all 12 patients immediately after implantation.

CONCLUSIONS: Transapical mitral valve replacement with the Tiara valve in high-risk patients with severe MR and aortic valve prostheses is technically feasible and can be performed safely.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты