MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-010-9382-z

Медицинская библиотека · International ophthalmology · 2010

Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma.

Bissig Alexandre, Feusier Michael, Mermoud André, Roy Sylvain

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The efficacy and safety of a newly designed Ex-PRESS X-200 drainage device for the surgical treatment of glaucoma was evaluated. A clinical, prospective, monocentric, non-randomised, unmasked study on patients with medically uncontrolled glaucoma was performed. A superficial scleral flap was created. A posterior deep sclerectomy (DS) was dissected without opening the Schlemm's canal and an Ex-PRESS X-200 device was inserted under the scleral flap into the anterior chamber to drain aqueous humour into the intrascleral space. Biomicroscopy, best-corrected visual acuity (BCVA), applanation intra-ocular pressure (IOP) measurements, and fundus examination were performed before surgery, on the first day, the first week, and 1, 2, 3, 6, 12 and 18 months after surgery. The mean follow-up was 18.6 ± 2.4 months (mean ± SD) for the 26 eyes that were treated with the Ex-PRESS X-200 device. Pre-operatively, the mean BCVA was 0.6 ± 0.3, the mean IOP was 22.0 ± 5.1 mmHg, and the mean number of medications per patients was 2.8 ± 0.8. Eighteen months after surgery the mean BCVA was 0.5 ± 0.4, the mean IOP was reduced to 12.0 ± 3.9 mmHg, and the mean number of medications per patient was 0.6 ± 1.2. Eighty-five percent of patients achieved an IOP < 18 mmHg with or without medication and 69% without medication. Post-operative complications were hyphaema (15%), Seidel (15%), encysted blebs (54%) and bleb fibrosis in 8% of patients. Mitomycin C(MMC) was administered to 15 patients (58%) with needling being performed on 10 (38%) of these patients. Mid-term results of DS with the Ex-PRESS X-200 implant demonstrated its efficacy in controlling IOP with few post-operative complications in difficult eyes with an increased risk of surgery failure.

Для цитирования: Bissig Alexandre, Feusier Michael, Mermoud André, Roy Sylvain. Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma.. International ophthalmology. 2010. DOI: 10.1007/s10792-010-9382-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.