Acta ophthalmologica · 2009
The effect of deep sclerectomy on intraocular pressure of normal-tension glaucoma patients: 1-year results.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Suominen Sakari, Harju Mika, Ihanamäki Tapio, Vesti Eija
Аннотация
PURPOSE: To study the intraocular pressure (IOP)-reducing effect of deep sclerectomy on normal-tension glaucoma (NTG) patients.
METHODS: We retrospectively analysed 21 eyes of 18 consecutive NTG patients who had undergone deep sclerectomy with mitomycin-C and a collagen implant.
RESULTS: Median (range) preoperative IOP was 15.1 mmHg (9.3-20.8) and median follow-up time 13 months (12-18). At the 1-year follow-up visit, median IOP was significantly (P < 0.001) reduced to 10.5 mmHg (4-15) with median IOP reduction from preoperative values of 37% (12-78). Laser goniopuncture was performed in 10 eyes (48%) 1-16 months postoperatively. After 13 months' follow-up, a complete success at 20%, 25% and 30% IOP reduction levels was achieved in 67%, 62% and 52% of eyes, respectively. Few complications were encountered, but these included reduced visual acuity, problems with conjunctiva, microperforation, hyphaema, Dellen formation and encapsulated bleb. We encountered no complications related to postoperative hypotony.
CONCLUSION: Deep sclerectomy with a collagen implant and mitomycin-C was a safe and effective method for reducing IOP in NTG patients during 1-year follow-up.
METHODS: We retrospectively analysed 21 eyes of 18 consecutive NTG patients who had undergone deep sclerectomy with mitomycin-C and a collagen implant.
RESULTS: Median (range) preoperative IOP was 15.1 mmHg (9.3-20.8) and median follow-up time 13 months (12-18). At the 1-year follow-up visit, median IOP was significantly (P < 0.001) reduced to 10.5 mmHg (4-15) with median IOP reduction from preoperative values of 37% (12-78). Laser goniopuncture was performed in 10 eyes (48%) 1-16 months postoperatively. After 13 months' follow-up, a complete success at 20%, 25% and 30% IOP reduction levels was achieved in 67%, 62% and 52% of eyes, respectively. Few complications were encountered, but these included reduced visual acuity, problems with conjunctiva, microperforation, hyphaema, Dellen formation and encapsulated bleb. We encountered no complications related to postoperative hypotony.
CONCLUSION: Deep sclerectomy with a collagen implant and mitomycin-C was a safe and effective method for reducing IOP in NTG patients during 1-year follow-up.
Предметные рубрики MeSH
Absorbable ImplantsAgedAnterior ChamberCollagenConjunctival DiseasesFemaleFollow-Up StudiesHumansHyphemaIntraocular PressureIntraoperative CareIntraoperative ComplicationsLaser TherapyLow Tension GlaucomaMaleMiddle AgedMitomycinPostoperative ComplicationsPostoperative PeriodPuncturesReoperationRetrospective StudiesSclerostomyVisual Acuity