Corneal Biomechanics After Accelerated Cross-linking: Comparison Between 18 and 9 mW/cm2 Protocols.

Hashemi Hassan, Asgari Soheila, Mehravaran Shiva, Miraftab Mohammad, Ghaffari Reza, Fotouhi Akbar

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To determine 1-year corneal biomechanical changes after accelerated corneal cross-linking in patients with progressive keratoconus and compare them between 5-minute (18 mW/cm2) and 10-minute (9 mW/cm2) protocols.

METHODS

In this non-randomized clinical trial, cases in both groups were examined with the Corneal Visualization Scheimpflug Technology (Corvis ST; Oculus Optikgeräte GmbH, Wetzlar, Germany) at baseline and at 6 and 12 months after treatment. Extracted indices included intraocular pressure (IOP), central corneal thickness (CCT), first and second applanation times, lengths, and velocities (T1, T2, L1, L2, V1, and V2), highest concavity time (HCT), deformation amplitude (DA), peak distance between bending points, and radius of curvature.

RESULTS

Mean patient age, baseline maximum keratometry, CCT, and IOP were similar between groups. After adjusting for CCT and baseline values with repeated measures analysis of covariance, at 1 year after the procedure, IOP (13.14 ± 1.41 vs 12.12 ± 1.49 mm Hg, P = .034) and T1 (6.84 ± 0.20 vs 6.67 ± 0.23 ms, P = .036) were higher in the 5-minute group, but T2 (21.31 ± 0.27 vs 21.58 ± 0.28 ms, P = .007), HCT (16.06 ± 0.51 vs 16.31 ± 0.48 ms, P = .017), and DA (1.03 ± 0.09 vs 1.10 ± 0.08 mm, P = .028) were lower. Other inter-group differences were not statistically significant (all P > .050). All 1-year changes were independent of cone position (all P > .050).

CONCLUSIONS

At 1 year after cross-linking in cases of mild and moderate keratoconus, corneal biomechanics appeared stable or stronger than baseline with both 5- and 10-minute protocols. However, mild cases who had the 5-minute protocol showed better improvement based on Corvis ST indices. [J Refract Surg. 2017;33(8):558-562.].

Для цитирования: Hashemi Hassan, Asgari Soheila, Mehravaran Shiva, Miraftab Mohammad, Ghaffari Reza, Fotouhi Akbar. Corneal Biomechanics After Accelerated Cross-linking: Comparison Between 18 and 9 mW/cm2 Protocols.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2017. DOI: 10.3928/1081597x-20170621-04.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.