MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jof9121140

Медицинская библиотека · Journal of fungi (Basel, Switzerland) · 2023

Finger-Prick Whole Blood Cryptococcal Antigen Lateral Flow Assay for the Diagnosis of Cryptococcosis in HIV-Negative Patients: A Case Series Study in Two Tertiary Centers in São Paulo, Brazil.

Vidal José E, Oliveira Fernanda Gurgel, Vieira Marcela, Pereira Luisa, Lucas Junior Rodovaldo M, Guedes Bruno Fukelman, Magri Marcello Chaves, Boulware David R

СтатьяПеревод в очереди

Аннотация

Cryptococcosis in HIV-negative patients can be an opportunistic or endemic disease. There are no published studies on the use of the finger-prick whole blood (point-of-care) cryptococcal antigen lateral flow assay (CrAg LFA) for diagnosing cryptococcosis in HIV-negative patients. We conducted a case series study of HIV-negative patients with cryptococcosis in two centers in São Paulo, Brazil. The objectives were to identify the sensitivity of a finger-prick whole blood CrAg LFA and to describe the main characteristics of this population. We identified 30 HIV-negative patients with cryptococcosis [19 (63%), male; median age, 47 years]. Ten (33%) patients were immunosuppressed, ten (33%) had other comorbidities, and ten (33%) were apparently immunocompetent and without comorbidities. The distribution of the sites of cryptococcosis was as follows: the central nervous system, 90% (n = 27); pulmonary, 43% (n = 13); and other extrapulmonary sites, 40% (n = 12). The sensitivity of the finger-prick whole blood CrAg LFA for the diagnosis of cryptococcosis was 97% (29/30). Among 26 participants with cryptococcal meningitis, the sensitivity of testing cerebrospinal fluid was as follows: CrAg latex agglutination, 77% (20/26); CrAg LFA, 96% (25/26); and culture, 81% (21/26). Culture speciation identified Cryptococcus gattii in 16 (62%) cases, and all had a positive finger-prick whole blood CrAg LFA. This test presented high sensitivity to the diagnosis of cryptococcosis in HIV-negative patients, including those caused by C. gattii.

Для цитирования: Vidal José E, Oliveira Fernanda Gurgel, Vieira Marcela, Pereira Luisa, Lucas Junior Rodovaldo M, Guedes Bruno Fukelman, Magri Marcello Chaves, Boulware David R. Finger-Prick Whole Blood Cryptococcal Antigen Lateral Flow Assay for the Diagnosis of Cryptococcosis in HIV-Negative Patients: A Case Series Study in Two Tertiary Centers in São Paulo, Brazil.. Journal of fungi (Basel, Switzerland). 2023. DOI: 10.3390/jof9121140.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.