MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsanm.4c02524

Медицинская библиотека · ACS applied nano materials · 2024

A Plasmonic Nanoledge Array Sensor for Selective Detection of Cardiovascular Disease Biomarkers in Human Whole Blood.

Tukur Frank, Mabe Taylor, Liu Mengxin, Tukur Panesun, Wei Jianjun

СтатьяПеревод в очереди

Аннотация

Optical sensors face challenges when detecting ultralow amounts of analytes in whole blood, including signal quenching due to optical absorption and false positives due to nonspecific binding. This study introduces gold nanoscale array features termed nanoledges (NLs), which interact with incident white light to produce a transmitted surface plasmon resonance (tSPR) signal. This extraordinary optical transmission (EOT) spectrum occurs in the near-infrared (NIR) region, thereby minimizing signal quenching caused by visible-light absorption from blood proteins and pigments. To develop a sensitive, selective, and label-free optical biosensor for detecting various levels of cardiac troponin I (cTnI) in very small volumes of whole blood samples, DNA aptamers are tethered to the NL surface, specifically binding to the cTnI biomarker. This biological binding activity alters the refractive index at the NL surface, causing a peak shift in the EOT spectrum and enabling quantification of cTnI levels. The NL array chip demonstrated high sensitivity for cTnI detection in buffer, human serum (HS), and human whole blood (HB), with detection limits of 0.079, 0.084, and 0.097 ng/mL, respectively. Control measurements using blank target mediums and those containing up to 125 ng/mL of other proteins, such as myoglobin, creatine kinase, and heparin, showed minimal interference and high specificity. The NL plasmonic array's performance in biosensing underscores its promise for clinical analysis and its potential development as a point-of-care platform for early cardiovascular disease (CVD) diagnostics.

Для цитирования: Tukur Frank, Mabe Taylor, Liu Mengxin, Tukur Panesun, Wei Jianjun. A Plasmonic Nanoledge Array Sensor for Selective Detection of Cardiovascular Disease Biomarkers in Human Whole Blood.. ACS applied nano materials. 2024. DOI: 10.1021/acsanm.4c02524.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.