The G-branch off-the-shelf mixed branch endograft for thoracoabdominal aortic aneurysm: 1-year results from a prospective multicenter study.

Guo Wei, Sun Guoyi, Zhang Hongpeng, Xin Shijie, Chen Zhong, Dai Xiangchen, Fu Weiguo, Chang Guangqi, Zhang Hongkun, Li Zhen, Gong Kunmei, Wu Xuejun, Guo Pingfan, Zhou Weimin, Yang Bin, Li Xiaoqiang

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The use of off-the-shelf multi-branched endografts for thoracoabdominal aortic aneurysm (TAAA) is increasing; however, these commercially available devices have limited anatomical feasibility for treating TAAA. This study aimed to assess the safety and efficacy of a novel G-branch off-the-shelf endograft for TAAA.

MATERIALS AND

METHODS

A total of 73 patients with TAAA were treated using the G-branch endograft at 14 sites across China. The primary endpoints were the 30-day technical success and major adverse events rates. The secondary endpoints were all-cause mortality, secondary intervention, endoleaks, target vessel patency, and freedom from renal function deterioration during a 1-year follow-up.

RESULTS

The technical success rate was 95.9% (70/73). Renovisceral artery reconstruction was successful in 99.7% (291/292) of patients. Within 30 days, six patients (8.2%) experienced major adverse events, namely paraplegia (n = 2), acute kidney injury (n = 2), acute myocardial infarction (n = 1), and cerebral infarction (n = 1). During the 1-year follow-up, one patient died from aortic dissection, giving an overall survival rate of 98.6%. Four patients (5.5%) underwent secondary interventions, giving a freedom from secondary intervention rate of 92.8%. Endoleaks occurred in 12 patients (10 type II, 2 type III). The primary patency rate of the target vessels was 95.7%, and three bridged stent grafts were successfully recanalized, resulting in a secondary patency rate of 96.7%. Renal function deterioration occurred in six patients (8.2%), giving a freedom from renal function deterioration rate of 94.6%.

CONCLUSIONS

The off-the-shelf G-Branch endograft appears safe, with favorable 30-day and 1-year mortality and morbidity rates for both elective and urgent TAAA treatment.

Для цитирования: Guo Wei, Sun Guoyi, Zhang Hongpeng, Xin Shijie, Chen Zhong, Dai Xiangchen, Fu Weiguo, Chang Guangqi, Zhang Hongkun, Li Zhen, Gong Kunmei, Wu Xuejun, Guo Pingfan, Zhou Weimin, Yang Bin, Li Xiaoqiang. The G-branch off-the-shelf mixed branch endograft for thoracoabdominal aortic aneurysm: 1-year results from a prospective multicenter study.. International journal of surgery (London, England). 2025. DOI: 10.1097/js9.0000000000003243.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.