Tabatabaei Seyed Ali, Soleimani Mohammad, Etesali Hamed, Naderan Morteza
Аннотация
PURPOSE: To assess the efficacy of swept-source optical coherence tomography (SS-OCT) and ultrasound biomicroscopy (UBM) in detecting posterior capsule (PC) defect in patients with traumatic cataract.
DESIGN: Observational case-series.
METHODS: Sixty-seven eyes from 67 patients, with traumatic cataract severe enough to prevent slit lamp evaluation of the PC, were included in a simple sequence without randomization. Patients underwent both 50-MHz UBM and SS-OCT evaluation of the PC by different operators. Cataract surgery was then performed using a single technique.
RESULTS: Sixty-seven eyes from 67 patients including 60 men and 7 women were studied. The mean age was 34 ± 14 years and the mean logarithm of minimal angle of resolution of visual acuity was 1.89 ± 0.71. The calculated sensitivity, specificity, and accuracy values for SS-OCT were 96.8% (95% confidence interval [CI] 83.81-99.43), 66.7% (95% CI 48.78-80.77), and 82% (95% CI 70.53-89.62), respectively. For UBM, sensitivity, specificity, and accuracy values were 82.6% (95% CI 62.86-93.02), 57.9% (95% CI 36.28-76.86), and 71.4% (95% CI 56.43-82.83), respectively. Positive predictive and negative predictive values for SS-OCT were 75% (95% CI 59.81-85.81) and 95.2% (95% CI 77.33-99.15) and for UBM were 70.4% (95% CI 51.52-84.15) and 73.3% (95% CI 48.05-89.1), respectively.
CONCLUSION: Although both imaging techniques are effective, SS-OCT appears to be at least comparable, or superior in special circumstances, to UBM in detecting preoperative posttraumatic PC rupture. We recommend preoperative assessment of all traumatic cataracts with SS-OCT as a part of surgical planning.
DESIGN: Observational case-series.
METHODS: Sixty-seven eyes from 67 patients, with traumatic cataract severe enough to prevent slit lamp evaluation of the PC, were included in a simple sequence without randomization. Patients underwent both 50-MHz UBM and SS-OCT evaluation of the PC by different operators. Cataract surgery was then performed using a single technique.
RESULTS: Sixty-seven eyes from 67 patients including 60 men and 7 women were studied. The mean age was 34 ± 14 years and the mean logarithm of minimal angle of resolution of visual acuity was 1.89 ± 0.71. The calculated sensitivity, specificity, and accuracy values for SS-OCT were 96.8% (95% confidence interval [CI] 83.81-99.43), 66.7% (95% CI 48.78-80.77), and 82% (95% CI 70.53-89.62), respectively. For UBM, sensitivity, specificity, and accuracy values were 82.6% (95% CI 62.86-93.02), 57.9% (95% CI 36.28-76.86), and 71.4% (95% CI 56.43-82.83), respectively. Positive predictive and negative predictive values for SS-OCT were 75% (95% CI 59.81-85.81) and 95.2% (95% CI 77.33-99.15) and for UBM were 70.4% (95% CI 51.52-84.15) and 73.3% (95% CI 48.05-89.1), respectively.
CONCLUSION: Although both imaging techniques are effective, SS-OCT appears to be at least comparable, or superior in special circumstances, to UBM in detecting preoperative posttraumatic PC rupture. We recommend preoperative assessment of all traumatic cataracts with SS-OCT as a part of surgical planning.
Предметные рубрики MeSH
AdultCataractCataract ExtractionEye Injuries, PenetratingFalse Positive ReactionsFemaleHumansLens, CrystallineMaleMicroscopy, AcousticMiddle AgedPosterior Capsular Rupture, OcularPosterior Capsule of the LensPredictive Value of TestsReproducibility of ResultsSensitivity and SpecificityTomography, Optical CoherenceVisual AcuityWounds, NonpenetratingYoung Adult