MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.12-0228

Медицинская библиотека · Chest · 2013

A novel extracorporeal CO(2) removal system: results of a pilot study of hypercapnic respiratory failure in patients with COPD.

Burki Nausherwan K, Mani Raj Kumar, Herth Felix J F, Schmidt Werner, Teschler Helmut, Bonin Frank, Becker Heinrich, Randerath Winfried J, Stieglitz Sven, Hagmeyer Lars, Priegnitz Christina, Pfeifer Michael, Blaas Stefan H, Putensen Christian, Theuerkauf Nils, Quintel Michael, Moerer Onnen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Hypercapnic respiratory failure in patients with COPD frequently requires mechanical ventilatory support. Extracorporeal CO2 removal (ECCO2R) techniques have not been systematically evaluated in these patients.

METHODS

This is a pilot study of a novel ECCO2R device that utilizes a single venous catheter with high CO2 removal rates at low blood flows. Twenty hypercapnic patients with COPD received ECCO2R. Group 1 (n = 7) consisted of patients receiving noninvasive ventilation with a high likelihood of requiring invasive ventilation, group 2 (n = 2) consisted of patients who could not be weaned from noninvasive ventilation, and group 3 (n = 11) consisted of patients on invasive ventilation who had failed attempts to wean.

RESULTS

The device was well tolerated, with complications and rates similar to those seen with central venous catheterization. Blood flow through the system was 430.5 ± 73.7 mL/min, and ECCO2R was 82.5 ± 15.6 mL/min and did not change significantly with time. Invasive ventilation was avoided in all patients in group 1 and both patients in group 2 were weaned; PaCO2 decreased significantly (P < .003) with application of the device from 78.9 ± 16.8 mm Hg to 65.9 ± 11.5 mm Hg. In group 3, three patients were weaned, while the level of invasive ventilatory support was reduced in three patients. One patient in group 3 died due to a retroperitoneal bleed following catheterization.

CONCLUSIONS

This single-catheter, low-flow ECCO2R system provided clinically useful levels of CO2 removal in these patients with COPD. The system appears to be a potentially valuable additional modality for the treatment of hypercapnic respiratory failure.

Для цитирования: Burki Nausherwan K, Mani Raj Kumar, Herth Felix J F, Schmidt Werner, Teschler Helmut, Bonin Frank, Becker Heinrich, Randerath Winfried J, Stieglitz Sven, Hagmeyer Lars, Priegnitz Christina, Pfeifer Michael, Blaas Stefan H, Putensen Christian, Theuerkauf Nils, Quintel Michael, Moerer Onnen. A novel extracorporeal CO(2) removal system: results of a pilot study of hypercapnic respiratory failure in patients with COPD.. Chest. 2013. DOI: 10.1378/chest.12-0228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.