DOI 10.1097/ico.0000000000002895

Медицинская библиотека · Cornea · 2021

Corneal Biometric Parameters and Refractive Properties in Microcornea With Normal Axial Length.

Jiang Zhaoxin, Wang Fangyu, Chen Zidong, Fan Yanmei, Xu Jiangang, Yu Minbin

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to evaluate the features of and relationships among corneal diameter, central corneal thickness (CCT), endothelial cell density (ECD), and corneal refractive properties in cases of microcornea (MC) with normal axial length.

METHODS

We included 22 patients (35 eyes) with MC and cataracts and 41 patients (48 eyes) with isolated cataracts as age-matched controls. They were divided into patients with MC younger than 18 years (MC-child), patients with MC 18 years or older (MC-adult), children with congenital cataracts (CCs), and adults with senile cataracts (SCs). Corneal diameter, axial and anterior chamber length, and keratometry were measured; central corneal endothelial cell imaging was performed.

RESULTS

The mean horizontal corneal diameter was 7.71 ± 1.51 and 8.78 ± 0.52 mm in MC-child and MC-adult groups, respectively, and 11.89 ± 0.59 and 11.52 ± 2.42 mm in child and adult controls, respectively. The mean CCT was 641.26 ± 63.37 (MC-child) and 617.38 ± 45.40 mm (MC-adult), and 554.92 ± 34.64 (CC) and 551.58 ± 28.47 mm (SC). The mean ECD was 2898.47 ± 443.90 (MC-child) and 2825.81 ± 484.65 cells/mm 2 (MC-adult), and 3155.13 ± 372.67 (CC) and 2749.33 ± 399.63 cells/mm 2 (SC). The average keratometry was 44.22 ± 3.14 D (MC-child) and 43.86 ± 2.59 D (MC-adult), and 44.19 ± 1.44 D (CC) and 43.94 ± 1.34 D (SC).

CONCLUSIONS

Patients with MC and normal axial length possess specific parameters, including significantly smaller corneal diameter and thicker CCT than the patients in the control groups. There were no significant differences in ECD and average keratometry. These parameters should be taken into account in the follow-up and treatment.

Для цитирования: Jiang Zhaoxin, Wang Fangyu, Chen Zidong, Fan Yanmei, Xu Jiangang, Yu Minbin. Corneal Biometric Parameters and Refractive Properties in Microcornea With Normal Axial Length.. Cornea. 2021. DOI: 10.1097/ico.0000000000002895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.