MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajoc.2019.100463

Медицинская библиотека · American journal of ophthalmology case reports · 2019

Electroretinograms before and after extraction of large intraocular iron foreign body.

Kumagai Tomoyuki, Matsumoto Celso Soiti, Kimura Itaru, Shinoda Kei

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful.

OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus. B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye. Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts. Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed. The decimal visual acuity improved to 1.2 two weeks later. The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye.

CONCLUSIONS AND

IMPORTANCE

We recommend that the physiology of the retina be assessed by recording ERGs with a skin-type electrode as soon as possible after a traumatic injury to the eye.

Для цитирования: Kumagai Tomoyuki, Matsumoto Celso Soiti, Kimura Itaru, Shinoda Kei. Electroretinograms before and after extraction of large intraocular iron foreign body.. American journal of ophthalmology case reports. 2019. DOI: 10.1016/j.ajoc.2019.100463.