MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-026-07218-z

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026

Intravitreal plungerless injector device (IPLID) for anterior chamber paracentesis: a novel approach to aqueous humor sampling.

Yepez Juan B, Murati Felipe A, Kozak Igor, Arevalo J Fernando

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the feasibility and preliminary safety of a plungerless intravitreal injector device (IPLID) adapted for aqueous humor aspiration during anterior chamber paracentesis.

METHODS

In this proof-of-concept pilot study, ten consecutive eyes undergoing diagnostic anterior chamber paracentesis with the IPLID were prospectively enrolled and compared with a retrospective cohort of ten eyes that underwent conventional syringe-based aspiration. Procedures were performed under slit-lamp visualization. Primary outcomes included feasibility and procedure duration. Secondary outcomes included aspirated volume, intraocular pressure (IOP) changes, wound integrity, patient discomfort (visual analogue scale), and surgeon-reported usability.

RESULTS

All procedures were successfully completed without intraoperative complications. The device achieved consistent aqueous humor aspiration (48 ± 5 µL) compared with greater variability using conventional methods (59 ± 17 µL). No anterior chamber instability or hypotony occurred. Wounds were self-sealing in all cases, whereas two control cases required bandage contact lenses. Procedure time was shorter and patient discomfort lower with the IPLID (p < 0.01). No adverse events were observed during one-week follow-up.

CONCLUSIONS

The plungerless intravitreal injector device appears to be a feasible and safe alternative for anterior chamber paracentesis, enabling controlled and reproducible aqueous humor sampling with improved procedural consistency and patient comfort. Larger prospective studies are warranted to confirm these findings and assess long-term safety.

Для цитирования: Yepez Juan B, Murati Felipe A, Kozak Igor, Arevalo J Fernando. Intravitreal plungerless injector device (IPLID) for anterior chamber paracentesis: a novel approach to aqueous humor sampling.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2026. DOI: 10.1007/s00417-026-07218-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.