MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s174211

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2018

Clinical outcomes of 4-point scleral fixated 1-piece hydrophobic acrylic equiconvex intraocular lens using polytetrafluoroethylene suture.

Patel Nimesh A, Shah Parth, Yannuzzi Nicolas A, Ansari Zubair, Zaveri Jill S, Relhan Nidhi, Williams Basil K, Kuriyan Ajay E, Henry Christopher R, Sridhar Jayanth, Haddock Luis, Fortun Jorge A, Albini Thomas A, Davis Janet L, Flynn Harry W

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the visual outcomes and complications of scleral fixated intraocular lenses (IOLs) using Gore-Tex suture.

METHODS

The current study is a retrospective noncomparative case series including patients who underwent scleral fixation of IOL (Akreos AO60) using Gore-Tex suture from August 2015 to March 2017 at a university teaching center. Primary outcome measures were visual acuity and complications at last follow-up.

RESULTS

The current study included 49 eyes of 48 patients. Mean follow-up duration postsurgery was 6.9 months (range: 0.9-29.4 months). The indications for secondary IOL surgery were dislocated IOL in 16/49 (33%), subluxed IOL in 9/49 (18%), dislocated or subluxed crystalline lens in 9/49 (18%), traumatic cataract in 8/49 (16%), and complicated cataract surgery in 7/49 (14%). Mean best-corrected logMAR visual acuity improved from 1±0.7 (20/200 Snellen equivalent) preoperatively to 0.5±0.5 (20/63 Snellen equivalent) at last follow-up. There were no intraoperative complications noted. Early postoperative complications included significant persistent corneal edema (longer than 1 week) in 4/49 (8.2%), ocular hypertension (intraocular pressure ≥25 mmHg) in 8/49 (16.3%), hypotony (intraocular pressure ≤5 mmHg) in 6/49 (12.2%), cystoid macular edema 3/21 (6.1%), IOL tilt 2/49 (4.1%), hyphema in 2/49 (4.1%), and vitreous hemorrhage in 5/49 (4.8%). There was one case of recurrent retinal detachment. One patient presented with an erosion of the Gore-Tex suture through the conjunctiva resulting in a purulent scleritis 6 months after the initial surgery, and was managed with removal of the IOL, debridement, and cryotherapy. Forty-one of 49 patients completed 3-month follow-up, among which visual acuity improved, deteriorated, or remained same compared to baseline in 27/49 (55.1%), 8/49 (16.3%), and 6/49 (12.2%) eyes, respectively.

CONCLUSION

In the current study, visual acuity outcomes were generally favorable. The complications were largely transient. Significant complications included a suture-related infection, which required removal of the IOL, and a recurrence of a retinal detachment.

Для цитирования: Patel Nimesh A, Shah Parth, Yannuzzi Nicolas A, Ansari Zubair, Zaveri Jill S, Relhan Nidhi, Williams Basil K, Kuriyan Ajay E, Henry Christopher R, Sridhar Jayanth, Haddock Luis, Fortun Jorge A, Albini Thomas A, Davis Janet L, Flynn Harry W. Clinical outcomes of 4-point scleral fixated 1-piece hydrophobic acrylic equiconvex intraocular lens using polytetrafluoroethylene suture.. Clinical ophthalmology (Auckland, N.Z.). 2018. DOI: 10.2147/opth.s174211.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.