MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.119108

Медицинская библиотека · Biosensors & bioelectronics · 2026

A one-pot proximity-triggered hybridization chain reaction ultrasensitive diagnosis platform for transfusion-transmitted infections.

Xue Zhenrui, Pan Shengnan, Wang Lu, Pan Ting, Diao Qizhi, You Minli, Yao Chunyan

СтатьяПеревод в очереди

Аннотация

Serological detection of viral antigens and antibodies remains central to transfusion-transmitted infection (TTI) screening, but current limitations in sensitivity and operational ease demand more advanced solutions. Here we present HCR Pro, a one-pot, wash-free platform that converts target-dependent proximity binding into an enzyme-free nucleic acid amplification signal. Specifically, dual-probe recognition brings oligonucleotide-conjugated capture probes into spatial proximity, triggering initiator strand release through competitive displacement within a thermodynamically stabilized blocker complex. This initiator strand triggers a hybridization chain reaction (HCR), generating fluorescence proportional to the target concentration. Using spiked samples, HCR Pro achieves limits of detection of 10.22 fg/mL for HBsAg, 0.23 fg/mL for HCV-core Ag, and 1.38 fg/mL for HIV-1 P24 Ag and performs antibody quantification of HIV-1 Ab down to 51.75 pg/mL over a range of 4.5 × 102 to 4.5 × 109 pg/mL. For a clinical sample set of 158 serum samples, HCR Pro distinguishes an infected set of samples from negative samples with an AUC value between 0.95 and 1.00, >94% sensitivity, and 100% specificity, requiring only 90 min and 15 μL of sample. The modular probe architecture allows target switching without re-optimizing the amplification backbone, positioning HCR Pro as a practical and adaptable screening platform for improving transfusion safety.

Для цитирования: Xue Zhenrui, Pan Shengnan, Wang Lu, Pan Ting, Diao Qizhi, You Minli, Yao Chunyan. A one-pot proximity-triggered hybridization chain reaction ultrasensitive diagnosis platform for transfusion-transmitted infections.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.119108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.