Intraoperative performance and long-term postoperative outcomes after scleral fixation of IOLs with polytetrafluoroethylene suture.

Bhojwani Deepak, Vasavada Abhay R, Vasavada Vaishali, Vasavada Shail, Praveen Mamidipudi R, Srivastava Samaresh

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report intraoperative performance and long-term postoperative outcomes after scleral fixation of intraocular lenses (IOLs) with polytetrafluoroethylene suture (PTFE).

SETTING

Raghudeep Eye Hospital, Ahmedabad, India.

DESIGN

Prospective, interventional case series.

METHODS

One hundred eyes undergoing scleral fixation of IOLs using PTFE suture (Gore-Tex) with 12 months or more postoperative follow-up were included. The primary outcome measures were occurrence of intraoperative and postoperative complications such as glaucoma, suture-related complications, and inflammation within the follow-up period. The secondary outcome measure was improvement in visual acuity (VA).

RESULTS

Of the 100 eyes, posteriorly dislocated IOLs (53 eyes) followed by dropped nuclei (33 eyes) were the most common surgical indications. Mean follow-up was 23 months (range 12 months to 5 years). Seventy-one patients (77.17%) had 18 months or more follow-up; 21 eyes had a rise in intraocular pressure in the early postoperative period; 12 of them required glaucoma surgery. Early complications were vitreous hemorrhage in 13 eyes, retinal detachment in 6 eyes, and transient hyphema in 1 eye. Late postoperative complications were cystoid macular edema (9 eyes), epiretinal membrane (3 eyes), and bullous keratopathy (3 eyes). Mean VA improved from 0.92 ± 0.16 (SD) logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.41 ± 0.27 logMAR. LogMAR at final follow-up was 0.41 ± 0.28 (P < .01). There were no cases of suture-related complications (erosion/breakage/granuloma) or IOL decentration throughout the follow-up period.

CONCLUSIONS

Scleral fixation of IOLs with PTFE suture was found to be safe and well tolerated. All eyes had well-centered IOLs, with no suture-related complications during long-term follow-up. VA improved significantly with acceptable postoperative complications.

Для цитирования: Bhojwani Deepak, Vasavada Abhay R, Vasavada Vaishali, Vasavada Shail, Praveen Mamidipudi R, Srivastava Samaresh. Intraoperative performance and long-term postoperative outcomes after scleral fixation of IOLs with polytetrafluoroethylene suture.. Journal of cataract and refractive surgery. 2020. DOI: 10.1097/j.jcrs.0000000000000309.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.